background image

This manual contains English. MM 313121

Graco Headquarters: Minneapolis

International Offices: Belgium, China, Japan, Korea

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441

Copyright 2008, Graco Inc. is registered to ISO 9001

www.graco.com

Revised 04/2009

Installation

*

Includes mix chamber and cleanout tool.

‡ When used with mix chamber FL0202 at 1000 psi 

(7.0 MPa, 70 bar).

1.

Remove the front cover retainer from the Fusion CS 
gun Thread the adapter (1) onto the mix chamber 
until it bottoms out.

2.

Insert the packing (3) through the center of the 
adapter (1) with the stepped end facing the mix 
chamber.

3.

Place the stud wall tip (2) onto the packing (3) and 
tighten the retaining ring (4) with light hand force.

4.

Adjust the FTM979 tip orientation with a standard 
5/16 in. nut driver (provided with gun). See F

IG

. 1.

Cleaning Tips

1.

If the pattern begins to shrink or becomes distorted, 
relieve pressure (see your gun manual) and clean 
the internal dome of the tip (2) with the tip cleanout 
tool (15D234). See F

IG

. 2.

2.

Clean out the inside diameter of the packing (3) and 
the flat mix chamber with a 0.94 in. (3/32 in, 2.39 
mm) dia. drill bit (Graco cleanout tool kit 246624).

3.

Add a thin layer of lubricant on the outside faces of 
the air cap (3) to ease cleaning.

This kit will not work with round mix chambers 
(i.e. RDXXXX). If there is a round mix chamber in 
the gun, replace it with a flat mix chamber. 
Smaller flat mix chambers can be ordered for 
lower fluid flow applications. See Flat Mix Cham-
ber Kit chart below.

Flat Mix 
Chamber Kit*

Type

Flow Rate (approx.) at 
1000 psi (7.0 MPa, 70 bar)

FL0202

Standard

15 lb/min (6.81 kg/min)

FL0101

Standard

11 lb/min (4.99 kg/min)

FL0000

Standard

7 lb/min (3.18 kg/min)

FL2020

Standard

3 lb/min (1.36 kg/min)

An FTM979 Stud Wall Tip is included in this kit. 
An FTM762 Stud Wall Tip is available for lower 
fluid flow applications as an accessory.

FTM979
Stud Wall Tip

FTM762
Stud Wall Tip

Pattern size

22 in. (559 mm)

14 in. (355.6 mm)

Spray distance 2 ft. (0.61 m)

2 ft. (0.61 m)

Fluid flow‡

15 lb/min 
(6.81 kg/min)

13 lb/min 
(5.90 kg/min)

The small plastic o-ring on the end of the flat mix 
chamber must be removed.

Overtightening may distort the packing inside the 
mix chamber. Reopen the hole with the 0.94 in. 
(3/32 in., 2.39 mm) drill bit provided if necessary.

TP100 tip only: adjust tip orientation prior to tight-
ening retaining ring (4).

F

IG

. 1

Instructions apply to stud wall tip only.

F

IG

. 2

TI3867a

TI4244a

End for Stud
Wall Tips

End for Air
Purge Tips