Operation
3A5414A
5
Operation
Once the Pulse HUB is installed, verify that
the power light (D) (F
IG
. 5) is ON and the HUB
is functioning correctly.
When the green power light (D) is illuminated
it indicates the unit is receiving AC power.
The status of the Pulse Fluid Management
Software is indicated by the HUB Status Light
(G) (F
IG
. 5). See HUB Status Lights table
below for diagnostic definitions.
HUB Diagnostics (D)
HUB Status Light (G)
NOTE:
On system boot the SBC will cycle through the LED status lights to confirm they are
functional.
F
IG
. 5
D
G
Indicator
Diagnostic Definition
No green power
light
Indicates that AC power is not connected. Verify that the power adapter is
securely plugged into the component and the AC power outlet
Verify that the AC power outlet is “live”.
Indicator
Diagnostic Definition
Solid Green with Blinking
Orange
HUB is running normally using Ethernet.
Solid Green with Blinking
Red
HUB is running normally using WiFi.
Blinking Green with
Blinking Orange
HUB is launching or updating using Ethernet.
Blinking Green with
Blinking Red
HUB is launching or updating using WiFi.
Solid Red
HUB has a critical systems failure.
Solid Red with Blinking
Orange
HUB has a critical systems failure with the device network.
Solid Red with Blinking
Green
HUB has a critical systems failure with the Pulse application.