Installation
Grounding
The equipment must be grounded to reduce the
risk of static sparking. Static sparking can cause
fumes to ignite or explode. Grounding provides an
escape wire for the electric current.
Pump: the pump is grounded with a wire connecting
the pump from the control enclosure. Locate the
small hole (W) in the pump outlet housing. Attach
the ground wire (Y) to the pump outlet housing using
the ground screw (X) supplied with your system.
Tighten the ground screw securely. Do not operate
the equipment without the ground wire in place.
Air compressor: follow manufacturer’s
recommendations.
Fluid supply container: follow your local code.
Object being dispensed to: follow your local code.
Figure 1 Grounding Screw
Connect to a Graco Air Motor
The displacement pump may be installed on Senator,
Bulldog, King, and NXT Graco air motors using Tie
Rod Kits. See kit manual for installation instructions.
Manual
Tie Rod Kit
Air Motor
334131
24V752
Bulldog
Senator
King
334132
24V754
NXT
334127A
7