4 Channel Upgrade Kit Installation
3A4404D
3
4 Channel Upgrade Kit Installation
1.
Perform the
Pressure Relief Procedure
(see the
InvisiPac manual).
2.
Place grounding wrist strap (1304) over your wrist
and secure other end to a grounded surface.
3.
Set the MZLP (1301) rotary switch to “2”.
4.
Remove screws (BB) then remove plate (AA) from
system.
5.
Use screws (BB) to install MZLP (1301) onto sys-
tem. Apply labels from label sheet (1308) to MZLP
#2. Place the “3” and “4” labels as shown in parts
illustration.
NOTE:
The new MZLP (1301) with be referred to as
MZLP 2, and the original MZLP that came with the sys-
tem will be referred to as MZLP 1 from here on.
6.
Remove electrical enclosure front access door.
NOTE:
Do not force the electrical connection. Minimal
force is required to seat the connector. If resistance is
felt, stop and verify the connector orientation. Verify the
connector has “Locked” by gently pulling on the white
connector housing.
7.
Connect CAN jumper cable (1302) to MZLP 1 con-
nector J3 and connect other end of jumper
cable (1302) to MZLP 2 connector J6.
8.
Connect power harness (1303) to MZLP 2 connec-
tor J2.
9.
Remove plugs (CC) from fluid manifold and replace
with straight fittings (1307) or the extra fittings
included with the InvisiPac system. Use the fittings
that meet your hose routing needs.
10. To ensure your InvisiPac system has the latest soft-
ware, insert token (1306) into the ADM. Follow the
Software Update Procedure
in the InvisiPac man-
ual.
The equipment must be grounded. Improper ground-
ing, setup, or usage of the system can cause electric
shock. Disconnect the plug from the power outlet or
turn off the circuit breaker for incoming power.
Equipment surfaces and fluid that is heated can
become very hot during operation. To avoid severe
burns, do not touch hot fluid or equipment.
J3
J6
J5
J9
J8
J2
J1
J9
J5
J6
J3
J2
J8
J1
MZLP 1
MZLP 2
Step 7: Install Jumper Cable (1302).