Setup
333233D
7
Install Vented Oil Cap Before
Using Equipment
The driver gear-box is shipped from the factory pre-filled
with oil. The temporary unvented cap (PX) prevents oil
leaks during shipment. This temporary cap must be
replaced with the vented oil cap (P), supplied with the
equipment, before use.
Setup
1.
Pull pressure adjustment knob (H) out and turn
counterclockwise until it stops. Push the knob in to
lock.
2. Turn power switch (E) OFF. Connect unit to power
source. See F
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1.
Pull pressure adjustment knob (H) out and turn
counterclockwise until it stops. Push the knob in to
lock.
2.
Relieve all fluid pressure as explained in your sepa-
rate sprayer manual.
Operation
The motor will adjust the speed to maintain a constant
fluid pressure.
1.
Pull the control knob (H) out to set. Turn the knob
clockwise to increase the pressure, or
counter-clockwise to decrease the pressure. Push
the knob to lock. See F
. 7.
F
IG
. 6: Unvented and Vented Oil Caps
F
IG
. 7: Pressure Adjustment Knob
PX
P
ti31010a
H
ti20171a_1
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.