Repair
Repair
Suggested Tools
• 5/8in. box end wrench or 5/8in. socket and ratchet
• Rubber mallet (to break items loose, if necessary)
102
135
105
135
102
104
137
125
122
126
103
109
112
120
140
133
134
119
114
110
111
108
107
121
123
115
106
124
113
4
11
5
5
8
12
ti22049a
Figure 2
See the figure at the beginning of this section.
NOTE: As items are disassembled, use a
soft brush and water or a compatible solvent
to clean components.
1. Perform Pressure Relief Procedure.
NOTICE
Ensure material pressure is relieved prior to
removing the fluid hose from the system.
2. Remove inlet and outlet hoses from pump lower.
3. Disconnect pump lower from motor and remove
pump lower from system.
4. While holding onto the inlet housing (109), use
a 5/8 in. wrench to loosen the two nuts on the
inlet housing clamp (102) then remove inlet
housing assembly (109 and 103).
6