Graco 24N719 Скачать руководство пользователя страница 3

Installation

3

Installation

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever 
you see this symbol.

1.

Close the supply pump’s bleed-type master air valve 
(required for pneumatic systems).

2.

Open the dispensing valve until pressure is fully 
relieved.

3.

Open the fluid valve at the pump fluid outlet. Leave 
the drain valve open until you are ready to use the 
system again.

If you suspect that the dispensing valve, extension, or 
grease fitting coupler is clogged, or that pressure has 
not been fully relieved after you have followed the steps 
above, 

very slowly

 loosen the coupler or hose end cou-

pling to relieve the pressure gradually, then loosen it 
completely. Then clear the clog.

Disassembly

1.

Relieve the pressure

2.

Fully extend the hose (1) and latch the reel.

3.

Attach a C-Clamp (A) to the reel flange to help pre-
vent the reel from unintentionally becoming 
unlatched and spinning freely (F

IG

. 1). 

4.

Remove hose stop from hose end and put all the 
parts in a safe place to reinstall on the new hose 
later (F

IG

. 2)

a.

Loosen and remove screws (aa) and nuts (bb).

b.

Separate two hose stop components (cc) to 

remove from end of hose.

5.

Disconnect hose (B) from swivel (C). ( F

IG

. 3)

This equipment stays pressurized until pressure is 
manually relieved. To help prevent serious injury from 
pressurized fluid, such as skin injection, splashing 
fluid and moving parts, follow the Pressure Relief 
Procedure when you stop spraying and before 
cleaning, checking, or servicing the equipment.

F

IG

. 1

Never allow the reel to spin freely. Doing so causes the hose 
reel to spin out of control, which could cause serious injury if 
you are hit by the hose or other moving parts.

F

IG

. 2

A

1

cc

aa

bb