Maintenance
Maintenance
Maintenance
Update
Update
Update Software
Software
Software
Manual 3A1244 will accompany any necessary
software updates. Follow all instructions and
warnings in Manual 3A1244 to update your DCM or
ADCM software.
Replace
Replace
Replace Battery
Battery
Battery
Replace the battery only if the clock stops functioning
after disconnecting power or a power failure.
Sparking can occur when changing the battery.
Replace the battery only in a non-hazardous
location, away from flammable fluids or fumes.
NOTICE
NOTICE
NOTICE
To avoid damaging the circuit board, wear a
grounding strap.
1.
Disconnect power.
2.
Remove the module from the bracket.
3.
Attach grounding strap.
4.
Remove 4 screws, and then remove the access
cover.
5.
Use a flathead screwdriver to pry out the old
battery.
NOTE:
NOTE:
NOTE: Dispose of battery properly in an
approved container and according to applicable
local guidelines.
6.
Replace with new battery. Ensure battery fits
under connector tabs before snapping other end
in place.
NOTE: Use only Panasonic CR2032 batteries for
replacement.
7.
Reassemble access cover and screws.
8.
Snap the module back into the bracket.
10
332013E