Pressure Relief Procedure

Installation

1.

Disconnect power.

2.

Relieve pressure.

3.

Remove plug (or in existing installations, proximity 
switch) from divider block o-ring port you will be 
using to install the proximity switch.

4.

Screw the proximity switch into the port. Torque to 
15 ft. lbs (20.3 N.m)

5.

Reconnect power source.

6.

Verify the yellow status indicator LED illuminates 
when the switch is compressed and there is power 
supplied to the divider block.

Technical Data and Dimensions

Graco Information 

TO PLACE AN ORDER, 

contact your Graco distributor or call to identify the nearest distributor.

Phone: 

612-623-6928

 or Toll Free: 

1-800-533-9655,

   Fax: 

612-378-3590

Relieve pressure

 in the system following the procedure 

recommended for your operating system or pump.

NOTICE

Electrical ratings must not be exceeded. Over-
load on a switch can cause switch to fail on the 
first cycle.

Never exceed pressure limits. Unit can be oper-
ated up to maximum pressure on a limited basis 
(i.e., set-up, testing) but continuous operation 
must be restricted to the designated adjustable 
range. Excessive cycling at maximum pressure 
limits could reduce sensor life. 

Electrical Design

DC PNP

Output

Normally open

Operating Voltage

10 - 36 VDC

Maximum Operating Pressure

5100 psi (35.1 MPa, 351 bar)

Ambient Temperature Range

-13° to 176°F (-25° to 80°C)

Current Rating

100 mA

Voltage Drop

<2.5 V

Current Consumption

<15 mA

Maximum Switching Frequency

100 Hz

Connection

M12

Thread type

7/16 inch

Sensing range

1.5 mm (f)

Display

Power Indicator: LED yellow

Wetted Parts

steel, chromium-plated, PBT

Weight

1.8 oz (0.053 kg)

Enclosure

(Ingression Protection) IP67

2.58 in. 
(65.5 mm)

Wiring Diagram

Dimensions

1