Instructions 

LDP5 (Preset) Electronic 

Metered Dispense Valves

For metered dispense of oils and antifreeze only. Do not dispense windshield washer 

solvent. For professional use only.

Not approved for use in European explosive atmosphere locations. 

Model 

1000 psi (6.9 MPa, 69 bar) Maximum Working Pressure

See page for model information.

Important Safety Instructions

Read all warnings and instructions in this 

manual before using the equipment. 

Save these instructions. 

Model 256216 Shown

Содержание 24F883

Страница 1: ...ld washer solvent For professional use only Not approved for use in European explosive atmosphere locations Model 1000 psi 6 9 MPa 69 bar Maximum Working Pressure See page 3 for model information Impo...

Страница 2: ...Menus 12 Resettable Total 12 Units of Measurement 13 Calibration 14 Auto Preset Amount 14 Shut Off Default Amount 15 LDP5 Meter Operation 16 Dispensing Fluid in Manual Mode 16 Dispensing Fluid in Auto...

Страница 3: ...Guard Swivel Cover Inlet Rigid Flex NPT BSPT BSPP LDP5 255277 X X LDP5 256216 X X X X LDP5 258694 X X X X LDP5 24F883 X X LDP5 24F884 X X X X LDP5 24F886 X X X X LDP5 24F889 X X LDP5 24F890 X X X X L...

Страница 4: ...mediately EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury Do not operate the unit when fatigued or under the influence of drugs or alcohol Do not exceed the maximum working pressure o...

Страница 5: ...not plug or unplug power cords or turn lights on or off when flammable fumes are present Use only grounded hoses Stop operation immediately if static sparking occurs or you feel a shock Do not use eq...

Страница 6: ...mp See Kits and Accessories page 27 for available kits Mounting Bracket Mounting bracket P N 196471 is available for resting dispense valve on the counsel FIG 2 FIG 1 B D E C A NOTICE Do not use this...

Страница 7: ...r existing installations skip to Electronic Control 1 and Gasket 2 Installation page 8 Flush the System 1 Close the fluid shut off valve B at each dispense position FIG 3 2 Make sure that the main flu...

Страница 8: ...3 Apply thread sealant to the male threads of the hose fitting 4 Thread the hose fitting into the swivel 4 and tighten firmly FIG 5 NOTE Make sure to let the sealant cure according to the manufacture...

Страница 9: ...will affect the performance of the nozzle 4 Open all of the dispense position shut off valves B ans start the pump to pressurize the system See LDP5 Meter Operation page 16 for proper operation of th...

Страница 10: ...p until it clicks into the locked position To unlock the trigger FIG 9 press on the smooth part of the trigger until it clicks out of the locked position When the trigger is released the fluid flow st...

Страница 11: ...displayed Further dispensing is allowed by pulling back the trigger and the display resumes counting Asleep Awake Mode Asleep is a battery saving mode where the display goes blank after 45 seconds of...

Страница 12: ...ght corner on the screen c Third screen Calibration Menu FIG 14 page 14 CAL blinks on the screen d Fourth screen Auto Preset Amount Menu FIG 15 page 14 AUTO blinks and the currently stored auto preset...

Страница 13: ...ement Menu is not already displayed complete steps 1 3 in Setup Menus page 12 2 GAL QTS PTS or LITERS blinks indicating the Units of Measurement Menu screen is displayed 3 Do one of the following a Pr...

Страница 14: ...e exactly one 1 liter of fluid into a calibrated one 1 liter container For proper calibration the exact amount must be dispensed b Press and hold the Manual Reset button until CAL stops blink ing c Wh...

Страница 15: ...et button b Press and hold the Auto Reset button to lock in the amount The Shut Off Default Amount Menu displays OR Press and hold the Auto Reset button to lock in the currently displayed auto preset...

Страница 16: ...DP5 Meter Operation Dispensing Fluid in Manual Mode 1 Press and hold the Man ual Reset button If the display is blank Asleep it wakes up and displays the amount dis played before it fell asleep If the...

Страница 17: ...e amount are dis played The factory default is 5 00 NOTE To change the stored preset dispense amount see Auto Preset Amount page 14 2 Dispensing or changing the displayed preset amount is done by one...

Страница 18: ...eleased NOTE When the trigger unlocks the automatic nozzle prevents the fluid in the extension from running out Viewing Totals To view the non resettable and resettable totals follow these instruction...

Страница 19: ...tracks the amount dispensed Options with any error code displayed as shown at right Press the Manual Reset button The error code is cleared the unit switches to Manual mode and the dispensed amount i...

Страница 20: ...e unit checks for flow every second and repeats the error code until the trigger is released and the error code cleared Err 5 The unit has dispensed the shut off default amount and has stopped fluid f...

Страница 21: ...th the meter settings See FIG 23 Replace the Filter 1 Follow the Pressure Relief Procedure page 10 2 Unscrew the hose from the swivel 4 FIG 24 3 Remove the o ring 8b and the filter 8a from inside of t...

Страница 22: ...age 10 Drain and dispose of fluids according to applicable regulations Refer to the material manufacturer s Safety Data Sheet Remove motors batteries circuit boards LCDs liquid crystal displays and ot...

Страница 23: ...o Reset button Slow or no fluid flow Filter is clogged 1 Relieve pressure by following the Pressure Relief Procedure page 10 2 Clean or replace the filter See Replace the Filter page 21 3 If the probl...

Страница 24: ...If flat the plate and seal are okay If the plate is not flat the meter is damaged Contact your Graco distributor for repairs or replacement Meter leaks from Automatic nozzle NOTE It is important to di...

Страница 25: ...949 1 2 34 8b 8a 8 6 4 4 5 3 26c 26c 26a 26a 26b 26b 35 32 38 17 1 11a 11b 11c 11d 11e 11f 2 11 3 Housing surface 3 must be clean to ensure proper adhesive bonding of gasket 2 6 Apply thread sealant w...

Страница 26: ...T nozzle flexible extension for oil and anti freeze includes 26a 26c models 255751 255277 258693 258694 2F881 24F883 24F885 24F886 24F887 24F889 24F891 24F892 1 26a EXTENSION 1 26b NOZZLE dispenser 1...

Страница 27: ...d Antifreeze Part No Description PSI MPa bar 112353 Diaphragm pump for fuel dis pense valve only 50 psi 0 34 MPa 3 4 bar 235998 Mini Fire Ball 225 3 1 600 psi 4 1 MPa 41 bar 237601 Fire Ball 425 3 1 6...

Страница 28: ...ile rubber zinc CS LCP Battery 9 volt alkaline Pressure loss at 5 gpm 90 psi 0 62 MPa 6 2 bar Accuracy 0 5 percent Units of Measurement pints quarts gallons liters factory set to quarts Maximum totali...

Страница 29: ...California Proposition 65 312668ZAC 29 California Proposition 65 CALIFORNIA RESIDENTS WARNING Cancer and reproductive harm www P65warnings ca gov...

Страница 30: ...in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WAR...