![Graco 24E512 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/graco/24e512/24e512_operation-and-repair-manual_2253085033.webp)
Troubleshooting
3A0232E
33
No solvent
No fluid in pressure pot
Refill pressure pot
Output valve closed
Open output valve
Check valve stuck closed
Increase pressure in pressure pot
Material check valve plugged
Clean and replace as needed
Solvent needle valve closed
Open solvent needle valve
Solvent check valve stuck closed
Ensure the solvent check valve opens freely
Solvent in cata-
lyst/resin mix
Solvent needle valve open
Close solvent needle valve
Solvent check valve o-ring damaged or
missing
Inspect and replace if necessary
Solvent valve damaged
Inspect and replace if necessary
Resin in solvent line
Solvent needle valve open
Close solvent needle valve
Solvent check valve o-ring damaged or
missing
Inspect and replace if necessary
Solvent valve damaged
Inspect and replace if necessary
AAC does not shut
off
AAC needle o-ring damaged (internal mix)
Inspect and replace if necessary
Atomized catalyst air
does not shut off
Atomized catalyst air Needle o-ring dam-
aged (external mix)
Inspect and replace if necessary
Air leakage
Air lines not fully seated in push lock tube
fittings
Ensure air lines are fully seated in fitting
Cutter Assembly pivot tube o-ring damaged
or missing
Inspect and replace if necessary
AAC/Atomized catalyst external needle
o-ring damaged
Inspect and replace if necessary
Cutter air valve seat damaged
Inspect and replace if necessary
G hook o-ring missing
Inspect and replace if necessary
Cutter mount o-ring missing
Inspect and replace if necessary