Warning
310648P
5
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just
a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
•
Do not point the gun at anyone or at any part of the body.
•
Do not put your hand over the spray tip.
•
Do not stop or deflect leaks with your hand, body, glove, or rag.
•
Do not “blow back” fluid; this is not an air spray system.
•
Follow Pressure Relief Procedure, page 19, when you stop spraying and before cleaning, check-
ing, or servicing equipment.
•
Use lowest possible pressure when flushing, priming, or troubleshooting.
•
Engage piston safety lock when not spraying.
•
Tighten all fluid connections before operating the equipment.
•
Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. High pres-
sure hose cannot be recoupled; replace the entire hose.
BURN HAZARD
Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe
burns, do not touch hot fluid or equipment. Wait until equipment/fluid has cooled completely.
EQUIPMENT MISUSE HAZARD
Misuse can cause serious injury or death.
•
For professional use only.
•
Use equipment only for its intended purpose. Call your Graco distributor for information.
•
Read manuals, warnings, tags, and labels before operating equipment. Follow instructions.
•
Check equipment daily. Repair or replace worn or damaged parts immediately.
•
Do not alter or modify equipment. Use only Graco parts and accessories.
•
Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
•
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings.
•
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
•
Do not kink or overbend hoses or use hoses to pull equipment.
•
Comply with all applicable safety regulations.
PRESSURIZED ALUMINUM PARTS HAZARD
Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids
containing such solvents in pressurized aluminum equipment. Such use can cause serious chemical
reaction and equipment rupture, and result in death, serious injury, and property damage.