background image

Warnings

309907P

3

Warnings

WARNINGS

FIRE AND EXPLOSION HAZARD 

Flammable fumes, such as solvent and paint fumes, in 

work area

 can ignite or explode. To help prevent 

fire and explosion:

Use equipment only in well ventilated area.

When flammable liquid is sprayed or used for flushing or cleaning, keep sprayer at least 20 feet (6 m) 
away from explosive vapors.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop 
cloths (potential static arc). 

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes 
are present.

Ground equipment and conductive objects in work area. See 

Grounding 

instructions.

If there is static sparking or you feel a shock, 

stop operation immediately.

 Do not use equipment 

until you identify and correct the problem.

ELECTRIC SHOCK HAZARD 

Improper grounding, setup, or usage of the system can cause electric shock.

Turn off and disconnect power cord before servicing equipment.

Use only grounded electrical outlets.

Use only 3-wire extension cords.

Ensure ground prongs are intact on sprayer and extension cords.

TOXIC FLUID OR FUMES HAZARD 

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swal-
lowed.

Read MSDS’s to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

EQUIPMENT MISUSE HAZARD 

Misuse can cause death or serious injury.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system com-
ponent. See 

Technical Data

 in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See 

Technical Data 

in all

 

equipment manuals. Read fluid and solvent manufacturer’s warnings.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not alter or modify equipment.

For professional use only.

Use equipment only for its intended purpose. Call your Graco distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not use hoses to pull equipment.

Comply with all applicable safety regulations.

Содержание 246857

Страница 1: ...Comp and 4900 ProComp Turbine Sprayers Models 246857 249524 and 249590 6 psi 41 MPa 0 4 bar Maximum Working Pressure Model 249768 8 psi 55 kPa 5 bar Maximum Working Pressure Related Manuals 309205 HVL...

Страница 2: ...y 20 Manual Conventions The following are general Warnings related to the safe setup use maintenance and repair of this equipment Addi tional more specific warnings may be found throughout the text of...

Страница 3: ...ing equipment Use only grounded electrical outlets Use only 3 wire extension cords Ensure ground prongs are intact on sprayer and extension cords TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can...

Страница 4: ...ure and result in death serious injury and property damage PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating servicing or when in the operating area of the eq...

Страница 5: ...paint passes to obtain coverage and saves on both material and clean up time See HVLP Turbine Gun manual 309205 310750 Korean for more information on the operation and use of the turbine spray gun Unp...

Страница 6: ...rovides dual air flow to motor and turbine F AIr filters pre filter and main Provides filtered air for turbine spray gun and turbine motor G Two speed switch Allows two speed operation of turbine spra...

Страница 7: ...s Reduce and catalyze all paint to manufacturer s specifi cations To compensate for the faster drying time of tur bine systems use a reducer that is one step slower than what is used for conventional...

Страница 8: ...If using a spray gun cup D Connect cup to gun fluid inlet E If using accessory remote pressure pots F Con nect fluid supply hose G between remote pressure pot fluid outlet H and gun fluid inlet E or...

Страница 9: ...or Remote Pressure Pot Spray Gun Cup Fill cup 3 4 full to keep air pressure tube clean Install cover Latch the under cup cover H to secure it to cup Fig 4 The overcup J has threads to secure it in pl...

Страница 10: ...2 Ensure turbine filter is clean before operating Clean filter page 11 Note To adjust spray gun pattern see HVLP Turbine Gun manual 309205 310750 Korean WARNING Page 3 Sparks can be expected during no...

Страница 11: ...ner 15 and pre filter 22 Fig 6 3 Remove main filter 21 and clean using one of the following methods Tap filter gently on flat surface dirty side down Direct compressed air 100 psi 7 bar 70 MPa maximum...

Страница 12: ...tube is loose Tighten Blow out and clear material hose Turbine not starting No power Check outlet for power Cycle red rocker switch Check that correct IEC modular cord is used and plugged in Check cir...

Страница 13: ...k 9 Slide turbine cover 1 on turbine base plate approximately 1 2 in to get it started 10 Reaching between the turbine cover 1 and base plate 2 carefully guide compressor air hose 84 and wiring harnes...

Страница 14: ...Repair 14 309907P FIG 7 FIG 8 64 84 b c e 1 2 d 88 ti3695a A...

Страница 15: ...ting parts and motor frame 6 Reassemble turbine 7 Run motor 30 to 45 minutes at half rated voltage to seat motor brushes Note If half rated voltage is not available run repaired unit in series with an...

Страница 16: ...Parts 16 309907P Parts HVLP 3800 Model 246897 and 249524 TI...

Страница 17: ...IGHT indicator 220V 1 34 114293 SWITCH rocker red 1 36 111593 SCREW grounding 1 37 102063 WASHER lock external tooth 1 38 114290 BREAKER circuit 8A 220V 1 39 192905 PLATE deflector 1 40 193059 GASKET...

Страница 18: ...07P Parts Drawing Model 249768 HVLP 4900 Procomp 7 23 41 10 65 12 38 36 67 37 68 7 27 6 2 4 85 86 72 64 20 21 6 26 1 83 6 80 88 25 82 24 19 18 46 32 40 5 47 4 6 27 14 13 81 28 26 27 29 22 15 16 17 74...

Страница 19: ...EW grounding 1 37 102063 WASHER lock external tooth 1 38 114290 BREAKER circuit 8A 240V 1 39 192905 PLATE deflector 1 40 193059 GASKET sensor 1 41 192845 GASKET duct 1 42 192846 GASKET duct 1 46 11428...

Страница 20: ...3 131 129 Ref No Part No Description Qty 101 104655 PRESSURE GUAGE 1 103 104815 PRESSURE REGULATOR 1 109 287818 POT 2 quart 1 9 liter aluminum 1 112 120132 GASKET 1 287821 GASKET KIT 5 pack 1 114 1699...

Страница 21: ...2 cfm Turbine stages 3800 3 4900 4 Maximum turbine hose length 60 ft 18 m Pressure pot volume 2 quart 1 9 liter Wetted parts Bare spray gun stainless steel brass hard coated aluminum Spray gun cup alu...

Страница 22: ...buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential los...