background image

Operation

309361F

5

Operation

Two Quart Pressure Cup

Pressure Relief Procedure

1.

On electrostatic guns only, turn the ES ON/OFF 
valve OFF.

2.

Turn off the gun air regulator (2) and the cup air reg-
ulator (10).

3.

Open the pressure relief valve all the way (counter-
clockwise) to bleed off pressure in the cup.

4.

Trigger the gun into a grounded metal waste con-
tainer to relieve the fluid pressure.

5.

Place the cup on a table and slowly unscrew the lid.

Daily Setup

1.

Fill the cup (1) with fluid. Fasten the lid securely.

2.

Turn on the main air supply.

3.

Turn the pressure relief valve fully clockwise.

4.

Set the gun air regulator (2) to 40 psi (0.28 MPa, 2.8 
bar) while spraying. Push the knob in to lock the reg-
ulator, pull out to unlock.

5.

Set the cup air regulator (10) to 10 psi (.07 MPa, 0.7 
bar). Push the knob in to lock the regulator, pull out 
to unlock.

6.

Spray a test panel. If the paint is not fully atomized, 
either decrease the fluid pressure using the cup air 
regulator or increase the setting of the gun air regu-
lator. 
To decrease the cup fluid pressure, turn the cup air 
regulator knob counterclockwise incrementally until 
you get the desired results.

Always use the lowest possible pressure needed to 
achieve the desired results.

WARNING

Pressurized Equipment Hazard

To reduce the risk of over-pressurizing the 
equipment, which could cause serious 
injury including splashing fluid in the eyes or 

on the skin, never exceed 50 psi (0.35 MPa, 3.5 bar) 
air pressure to the cup. The safety valve (9) is preset 
to relieve pressure at 50 psi (0.35 MPa, 3.5 bar). Do 
not alter the safety valve.

WARNING

Pressurized Equipment Hazard

The system pressure must be manually 
relieved to prevent the equipment from 
starting or spraying accidentally. To reduce 

the risk of an injury from accidental spray from the 
gun or splashing fluid, follow the Pressure Relief 
Procedure
 whenever you:

are instructed to relieve the pressure

stop spraying

check or service any of the system equipment

or disconnect any of the system equipment.

Содержание 244731

Страница 1: ...to I S EN ISO 9001 309361F Instructions Parts List Pressure Cups Part No 244731 Series A 1 Quart Size 20 psi 0 14 MPa 1 4 bar Maximum Working Fluid Pressure Part No 287301 Series A 2 Quart Size 50 ps...

Страница 2: ...Hazard Never use 1 1 1 trichloroethane methylene chlo ride other halogenated hydrocarbon solvents or flu ids containing such solvents in this equipment Such use could result in a serious chemical rea...

Страница 3: ...D Fluid Hose E Air Hose for electrostatic guns use the grounded air hose shown F Air Hose Ground Wire used on electrostatic guns only G Air Spray Gun electrostatic gun shown 4 Gun Air Regulator 6 Cup...

Страница 4: ...er decrease the fluid pressure using the cup air regulator or increase the setting of the gun air regu lator To decrease the cup fluid pressure turn the cup air regulator knob counterclockwise increme...

Страница 5: ...her decrease the fluid pressure using the cup air regulator or increase the setting of the gun air regu lator To decrease the cup fluid pressure turn the cup air regulator knob counterclockwise increm...

Страница 6: ...the gun 7 Relieve the pressure 8 Remove the solvent from the cup and wipe the equipment with a solvent dampened rag 9 Assemble the empty cup and set the cup air regula tor to 10 psi 07 MPa 0 7 bar Spr...

Страница 7: ...r at 10 psi 07 MPa 0 7 bar and spray into a waste container until clean solvent comes from the gun 6 Relieve the pressure 7 Remove the solvent from the cup and wipe the equipment with a solvent dampen...

Страница 8: ...Parts 8 309361F Parts Part No 244731 Pressure Cup 1 Quart 2 20 22 22 8 9 17 4 14 6 13 11 3m 3j 3d 3h 19 18 12 16 3e 3f 3g 3a 3b 3c 3k 15 11 5 7 21 23 10 11 A A B B 22 TI1639b...

Страница 9: ...pressure air gun 1 6 116904 REGULATOR air pressure cup 1 7 111500 GAUGE pressure air cup 1 8 110440 TEE 1 9 112059 VALVE safety 1 10 189557 RESTRICTOR air 1 11 112698 ELBOW 3 12 104008 WASHER lock 1 1...

Страница 10: ...Parts 10 309361F Part No 287301 Pressure Cup 2 Quart 1 1 7 1 1 16 11 10 6 8 3 2 4 6 5 12 8 14 13 21 15 9 22 A A B B 23 ti1643d...

Страница 11: ...pressure cup 2 qt 1 10 116903 REGULATOR air 1 11 104655 GAUGE pressure air cup 1 12 110440 TEE branch male 1 8 npt 1 13 189557 RESTRICTOR air regulator 1 14 115671 FITTING connector male 1 15 100133 W...

Страница 12: ...pairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INC...

Отзывы: