3
309276
Installation
Mount the Converter
Mount the converter (Fig.1) to the wall or other secure
surface using the mounting holes. Do not let the unit
hang unsecured.
CAUTION
Do not mount the pulse converter near a heat source.
Connect the Converter
NOTE:
When connecting the converter to the pulse
meter, use only the connecting cables permanently
attached to each unit. Do not use extension cables to
lengthen the distance between the pulse meter and the
converter.
A distance greater than 24 inches (61
cm) between the units can degrade the signal.
1. Turn off the Electronic Fluid Commander and
unplug it.
2. Connect the converter to the pulse meter first
using the connector with two female sockets.
3. Connect the converter to the Electronic Fluid
Commander (EFC) using the remaining male
connector.
4. Plug in the Electronic Fluid Commander and turn
on the switch at the rear of the control.
Note:
During power--up, all display segments must
show and all stations and dispense lights must light
steadily for 3 to 4 seconds. When the display shows
four dashes, enter your security code. (Refer to the
Electronic Fluid Commander manual for details).
Fig. 1
Female connector
to Pulse Meter
(Graco part number
215474)
Male connector
to EFC
Mounting holes
Mounting holes
TI0708B
Technical Data
Pulse Converter Technical Data
Category
Data
Operating temperature
--4
_
F (--20
_
C) to 176
_
F (80
_
C)
Max. VDC
15 VDC at 20mA
Wiring Gauge Required
18 AWG 2 wire / 90V
Wiring Polarity
Red = + (positive)
g
y
Black = -- (negative)