background image

308645

3

WARNING

INJECTION HAZARD

Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely
serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also
cause serious injury.

D

Fluid injected into the skin might look like just a cut, but it is a serious injury. 

Get immediate medi-

cal attention.

D

Do not point the gun at anyone or at any part of the body.

D

Do not put your hand or fingers over the spray tip.

D

Do not stop or deflect leaks with your hand, body, glove or rag.

D

Do not “blow back” fluid; this is not an air spray system.

D

Always have the tip guard and the trigger guard on the gun when spraying.

D

Check the gun diffuser operation weekly. See page 8.

D

Be sure the gun trigger safety operates before spraying.

D

Lock the gun trigger safety when you stop spraying.

D

Follow the 

Pressure Relief Procedure

 on page 5 if the spray tip clogs and before cleaning,

checking or servicing the equipment.

D

Tighten all fluid connections before operating the equipment.

D

Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. 
Do not repair high pressure couplings; you must replace the entire hose.

D

Fluid hoses must have spring guards on both ends, to help protect them from rupture caused by
kinks or bends near the couplings.

MOVING PARTS HAZARD

Moving parts can pinch or amputate your fingers.

D

Keep clear of all moving parts when starting or operating the pump.

D

Before servicing the equipment, follow the

 Pressure Relief Procedure

 on page 5 to prevent the

equipment from starting unexpectedly.

RECOIL HAZARD

Due to the high pressure fluid emitted, a strong recoil action may occur when you trigger this gun. If
you are unprepared, your hand could be forced back toward your body or you could lose your balance
and fall, resulting in serious injury.

Содержание 238350

Страница 1: ...SSURE Model 238350 Series A Includes RACr DripLesst Guard 515 size SwitchTipt and 4 finger trigger Model 824004 Series A Includes RACr DripLesst Guard 515 size SwitchTipt and 4 finger trigger Model 23...

Страница 2: ...urpose If you are not sure call your Graco distributor D Do not alter or modify this equipment D Check equipment daily Repair or replace worn or damaged parts immediately D Do not exceed the maximum w...

Страница 3: ...y when you stop spraying D Follow the Pressure Relief Procedure on page 5 if the spray tip clogs and before cleaning checking or servicing the equipment D Tighten all fluid connections before operatin...

Страница 4: ...n the spray area D Extinguish all open flames or pilot lights in the spray area D Do not smoke in the spray area D Do not turn on or off any light switch in the spray area while operating or if fumes...

Страница 5: ...st be manually relieved to prevent the system from starting or spraying accidentally Fluid under high pressure can be injected through the skin and cause serious injury To reduce the risk of an injury...

Страница 6: ...p wear 7 If adjusting the pressure does not give a good spray pattern follow the Pressure Relief Proce dure on page 5 and then try another tip size 8 Use a full open full close triggering action Hold...

Страница 7: ...andard Flat Tip and Guard 1 Lock the gun trigger safety open the pressure drain valve CAUTION Never soak the entire gun in solvent Prolonged exposure to solvent can ruin the packings 2 Remove the spra...

Страница 8: ...rd and spray tip 3 Start the sprayer and adjust it to the lowest pressure 4 Aim the gun into a grounded metal pail while holding it firmly to the pail Trigger the gun If the fluid emitted is not diffu...

Страница 9: ...ip Soak and clean the parts 3 Put the pump intake in a grounded pail of water or solvent 4 Start the pump at its lowest pressure 5 Trigger the gun into the original pail When water or solvent appears...

Страница 10: ...and diffuser seat A Torque the diffuser seat to 26 32 ft lb 35 43 N m 4 If the gun handle 6 was removed hand tighten it into the fluid housing 26 it should fit easily 5 Adjust the needle before using...

Страница 11: ...ent 4 Remove swivel 15 guard retainer 42 and cushion o ring 43 5 Save guard retainer and cushion o ring 05968 Fig 10 6 12 42 43 15 Reassembly 1 Clean internal thread of handle 6 2 Install guard retain...

Страница 12: ...Drawing n41 n40 12 5 42 16 20 18 21 22n 23 26 32 37 1 31 33 1 Included with 1 Model 238350 Series A Model 824004 Series A Model 239045 Series A 1 Purchase separately 2 2 6 43 15 05962 17 45 45 2 Inclu...

Страница 13: ...AINER ELEMENT 1 standard 50 mesh 20 179763 SPRING 1 21 179722 SPRING RETAINER color coded blue for standard 50 mesh filter 1 22n 179733 GASKET 1 23 191244 END CAP 1 26 190973 FLUID HOUSING 1 31 105334...

Страница 14: ...rds is included with every Graco airless gun 237859 RACR DripLesst Guard Order SwitchTip separately See your distributor for available sizes 220222 Standard DripLesst Tip Guard Order flat tip separate...

Страница 15: ...t 1 4 npsm m swivel Maximum Material Temperature 120_F 50_C Sound Data Sound Pressure Level 78 dB A Sound Power Level 87 dB A Measured while spraying waterbase paint gravity 1 36 through a 517 tip at...

Страница 16: ...but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach...

Отзывы: