18 308-324
Mechanical Technical Data
Maximum Working Fluid Pressure
3000 psi
. . . . . . .
(210 bar)
Flow Range
Models PPM 3050H
0.01–0.5 gal/min
. . . . . . . . . . . .
(38–1900 cc/min)
Models PPM 3100H
0.02–1.0 gal/min
. . . . . . . . . . . .
(75–3800 cc/min)
Models PPM 3550H
0.1–5.5 gal/min
. . . . . . . . . . . . .
(380–21,000 cc/min)
Flow Meter Connector Size
M12 x 1.5(m)
. . . . . . . . . .
x 1/4 npt(f)
Flow Meter Inlet/Outlet Size
without Connector
M12 x 1.5(m)
. . . . . . . . . . . . . . . . . .
Maximum Fluid Temperature
250
_
F
. . . . . . . . . . . . .
120
_
C)
Fluid Viscosity Range
15,000 cps
. . . . . . . . . . . . . . . . .
(Refer to the Pressure Drop Curve, below)
Wetted Parts
303 & 321 Stainless Steel,
. . . . . . . . . . . .
Tungsten Carbide, PTFE
Pressure Drop Curve
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55
Flow Rate
For most commonly
used coatings, the flow
meter will provide
accurate flow readings
to 0.5%.
PSI
GAL/MIN
0
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1.10
0
0.32
0.65
0.97
1.30
1.62
1.94
2.27
2.59
2.92
3.24
3.43
PPM 3050H
PPM 3100H
PPM 3550H