background image

18

308198

Technical Data

Part No.

Pump Model

Displacement
Pump Part No.

Ratio

Maximum 
Fluid Working
Pressure

Maximum
Pump Air Input
Pressure

Maximum Air
Inlet Pressure

231168

Monark

r

222839

23:1

285 bar, 29 MPa
(4140 psi)

12 bar, 1.2 MPa 
(180 psi)

12 bar, 1.2 MPa 
(180 psi)

231169

President

r

222907

46:1

317 bar, 32.0
MPa (4600 psi)

7 bar, 0.7 MPa 
(100 psi)

10 bar, 1.0 MPa 
(150 psi)

Wetted  parts

For wetted parts information, refer to your separate component manuals.

Sound Pressure Levels (dBa)

(measured at 1 meter from unit)

Input Air Pressures at 15 cycles per minute

Air Motor

40 psi (0.28 MPa, 2.8 bar)

70 psi (0.48 MPa, 4.8 bar)

100 psi (0.7 MPa, 7 bar)

President

73.6 dB(A)

78.3 dB(A)

80.9 dB(A)

Monark

62.6 dB(A)

62.5 dB(A)

63.9 dB(A)

Sound Power Levels (dBa)

(tested in accordance with ISO 9614–2)

Input Air Pressures at 15 cycles per minute

Air Motor

40 psi (0.28 MPa, 2.8 bar)

70 psi (0.48 MPa, 4.8 bar)

100 psi (0.7 MPa, 7 bar)

President

87.4 dB(A)

92.1 dB(A)

94.6 dB(A)

Monark

69.5 dB(A)

70.7 dB(A)

71.0 dB(A)

Manual Change Summary

Red-Handled Air Bleed Valve (60) and attaching parts are added to these assemblies.

Sound levels for Monark air motors have been reduced.

Содержание 231169

Страница 1: ...rtant warnings and information READ AND KEEP IT FOR REFERENCE 19 LITER 5 GALLON SIZE Ram Mounted Pumps CHECK MATET 200 STAINLESS STEEL DISPLACEMENT PUMPS For Pump Model Nos Ratios and Working Pressure...

Страница 2: ...ber 20 List of Models Part No Series Pump Model Displacement Pump Model Ratio Maximum Fluid Working Pressure Maximum Pump Air Input Pressure Maximum Air Inlet Pressure 231168 B Monarkr 222839 23 1 285...

Страница 3: ...utor D Do not alter or modify this equipment D Check equipment daily Repair or replace worn or damaged parts immediately Use only genuine Graco parts D Do not exceed the maximum working pressure state...

Страница 4: ...gun valve trigger safety when you stop spraying D Follow the Pressure Relief Procedure on page 11 if the spray tip nozzle clogs and before clean ing checking or servicing the equipment D Tighten all...

Страница 5: ...including solvent rags and gasoline D Electrically disconnect all equipment in the spray dispense area D Extinguish all open flames or pilot lights in the spray dispense area D Do not smoke in the sp...

Страница 6: ...6 308198 Notes...

Страница 7: ...surface Do not place the pail on a nonconductive surface such as paper or cardboard which interrupts the grounding continu ity 8 To maintain grounding continuity when flushing or relieving pressure h...

Страница 8: ...air regulator H D The pump air regulator H controls pump speed and outlet pressure by adjusting the air pressure to the pump Locate the regulator close to the pump but upstream from the pump air blee...

Страница 9: ...Type Master Air Valve for accessories L Fluid Drain Valve required M Fluid Pressure Regulator N Airless Spray Gun or Dispensing Valve P Gun Valve Swivel R Electrically Conductive Fluid Supply Hose S E...

Страница 10: ...eep it clean The kit includes ten disposable polyethylene shields The shields may be reused if desired by removing excess material with a squeegee To use place one shield on the surface of the fluid b...

Страница 11: ...he tip guard retaining nut or hose end coupling and relieve pressure gradually then loosen completely Now clear the tip nozzle or hose Starting and Adjusting the Ram 1 Refer to Fig 3 Close all air reg...

Страница 12: ...entire pail from the ground When the pail is empty follow this procedure to load a new pail of material 1 Stop the pump A by closing the pump air bleed valve G 2 Before raising the wiper plate locate...

Страница 13: ...mp Air Bleed Valve required for pump H Pump Air Regulator T Ram Air Regulator U Ram Director Valve V Red Handled Main Air Bleed Valve X Air Release Valve JJ Pump Bleeder Valve KK Wiper Plate Vent Hand...

Страница 14: ...Part No 231168 Series B 23 1 Ratio Monark Pump with Check Mate 200 Stainless Steel Displacement Pump 06758D 1 3 4 5 6 Ref 11 11 Ref 13 21 22 23 24 26 27 19 29 28 32 33 34 36 37 39 38 30 6b 42 41 40 4...

Страница 15: ...er 8 oz not shown 1 19 159239 NIPPLE pipe 3 8 npt m x 1 2 npt m 1 21 162376 MANIFOLD air swivel 1 2 npt m x 1 2 npt f swivel three 1 8 npt f ports 1 22 100960 GAUGE air pressure 0 14 bar 0 1 4 MPa 0 2...

Страница 16: ...rt No 231169 Series B 46 1 Ratio President Pump with Check Mate 200 Stainless Steel Displacement Pump 06755D 1 3 4 5 6a Ref 11 11 Ref 19 21 22 23 42 26 27 28 29 30 32 33 34 36 37 38 39 43 53 6a 2 6b 2...

Страница 17: ...0 5 liter 8 oz not shown 1 19 158491 NIPPLE pipe 1 2 npt 2 21 162376 MANIFOLD air swivel 1 2 npt m x 1 2 npt f swivel three 1 8 npt f ports 1 22 100960 GAUGE air pressure 0 14 bar 0 1 4 MPa 0 200 psi...

Страница 18: ...e Levels dBa measured at 1 meter from unit Input Air Pressures at 15 cycles per minute Air Motor 40 psi 0 28 MPa 2 8 bar 70 psi 0 48 MPa 4 8 bar 100 psi 0 7 MPa 7 bar President 73 6 dB A 78 3 dB A 80...

Страница 19: ...el A Raised B Lowered C D E F G Weight 231168 1606 mm 63 23 in 1210 mm 47 64 in 279 mm 11 in 356 mm 14 in 356 mm 14 in 432 mm 17 in 546 mm 21 5 in 79 kg 174 lb 231169 1683 mm 66 26 in 1287 mm 50 67 in...

Страница 20: ...warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or...

Отзывы: