background image

307621

3

WARNING

INJECTION HAZARD

Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely
serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also
cause serious injury.

D

Fluid injected into the skin might look like just a cut, but it is a serious injury. 

Get immediate medi-

cal attention.

D

Do not point the gun at anyone or at any part of the body.

D

Do not put your hand or fingers over the spray tip.

D

Do not stop or deflect leaks with your hand, body, glove or rag.

D

Do not “blow back” fluid; this is not an air spray system.

D

Always have the tip guard and the trigger guard on the gun when spraying.

D

Check the gun diffuser operation weekly. Refer to the gun manual.

D

Be sure the gun trigger safety operates before spraying.

D

Lock the gun trigger safety when you stop spraying.

D

Follow the 

Pressure Relief Procedure

 on page 8 if the spray tip clogs and before cleaning,

checking or servicing the equipment.

D

Tighten all fluid connections before operating the equipment.

D

Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. 
Do not repair high pressure couplings; you must replace the entire hose.

MOVING PARTS HAZARD

Moving parts, such as the air motor piston, can pinch or amputate your fingers.

D

Keep clear of all moving parts when starting or operating the pump.

D

Before servicing the equipment, follow the

 Pressure Relief Procedure

 on page 8 to prevent the

equipment from starting unexpectedly.

Содержание 226970

Страница 1: ...D 23 1 Ratio Monarkr Hydra Sprayr Sprayers 2760 psi 19 MPa 190 bar Maximum Fluid Working Pressure 120 psi 0 8 MPa 8 bar Maximum Air Inlet Pressure Part No 226970 Series B With Agitator Part No 231114...

Страница 2: ...ntended purpose If you are not sure call your Graco distributor D Do not alter or modify this equipment D Check equipment daily Repair or replace worn or damaged parts immediately D Do not exceed the...

Страница 3: ...uard on the gun when spraying D Check the gun diffuser operation weekly Refer to the gun manual D Be sure the gun trigger safety operates before spraying D Lock the gun trigger safety when you stop sp...

Страница 4: ...debris including solvent rags and gasoline D Electrically disconnect all equipment in the spray area D Extinguish all open flames or pilot lights in the spray area D Do not smoke in the spray area D...

Страница 5: ...B in the air line to isolate the air line components for servicing Install an air line moisture trap and drain valve C to help re move moisture from the compressed air supply Keep the site clear of an...

Страница 6: ...0 includes a 60 mesh 250 micron stainless steel element to filter particles from the fluid as it leaves the pump D The fluid drain valve 20 is required in your system to relieve fluid pressure in the...

Страница 7: ...Air Valve required for pump 2 Air Line Bushing 3 Drain Valve Elbow 5 Air Regulator 6 Fluid Supply Hose 7 Pump 9 Airless Spray Gun 10 Fluid Filter 20 Fluid Drain Valve required 21 19 Liter 5 Gallon Pa...

Страница 8: ...ogged or that pressure has not been fully relieved after following the steps above very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually then loosen comple...

Страница 9: ...gun 9 as explained in the gun manual 2 Open the air regulator 5 slowly Use the regulator to control pump speed and fluid pressure Always use the lowest air pressure necessary to get the desired result...

Страница 10: ...luid you are pumping and with the wetted parts in your system Check with your fluid manufacturer or supplier for recommended flushing fluids and flushing frequency CAUTION Never leave water or water b...

Страница 11: ...Elbow 5 Air Regulator 6 Fluid Supply Hose 7 Pump 9 Airless Spray Gun 10 Fluid Filter 20 Fluid Drain Valve required 21 19 Liter 5 Gallon Pail 27 Air Manifold 57 Ground Wire required see page 5 for inst...

Страница 12: ...art No 231114 Series A includes items 1 57 05982 1 A A 7 55 1 2 5 22 17 27 17 26 4 18 12 19 33 29 23 42 41 43 45 44 21 8 13 15 9 6 32 16 19 12 54 51 30 46 51 Ref 50 52 53 39 24 30 10 3 20 11 57 1 1 Pa...

Страница 13: ...REW self tap type f no 8 32 3 8 10 mm long 2 20 210657 DRAIN VALVE see 306861 for parts 1 21 101108 PAIL 5 gallon 19 liter 1 22 101180 GAUGE pressure air 0 200 psi 0 14 bar range 1 23 101962 SCREW soc...

Страница 14: ...B includes items 1 59 05981 1 A A 7 55 1 2 5 22 17 27 26 4 18 23 42 41 43 45 44 21 8 13 15 9 6 32 16 19 12 54 51 30 46 51 Ref 50 52 53 39 24 30 10 3 20 11 57 1 Part of the pump 7 58 59a 59b 2 The agit...

Страница 15: ...parts 1 21 101108 PAIL 5 gallon 19 liter 1 22 101180 GAUGE pressure air 0 200 psi 0 14 bar range 1 23 101962 SCREW socket hd set 1 4 20 x 3 8 10 mm long 2 24 100509 PLUG pipe 1 4 npt 1 26 151519 NIPP...

Страница 16: ...Air inlet size 1 2 npt f at inlet fitting 3 8 npt f at pump Fluid outlet size at fluid filter 1 4 npt f Fluid inlet size 3 4 npt m Maximum operating temperature 82_C 180_F Sound level at 120 psi 25 cy...

Страница 17: ...307621 17 Dimensions 05983 Model 226970 Shown A B Pump Model A B Weight 231114 29 in 737 mm 13 in 330 mm 48 lb 22 kg 226970 29 in 737 mm 13 in 330 mm 50 lb 23 kg...

Страница 18: ...l be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other inc...

Отзывы: