27
308302
Technical Data
0
100
200
300
400
500
600
700
800
900
1000
0
4
8
12
16
20
24
28
32
FLUID FLOW (TEST FLUID: 250,000 CENTIPOISE)
oz/min
cc/min
To find Fluid Outlet Pressure (MPa/bar/psi) at a specific fluid flow (ccm
or oz/min) and operating air pressure (MPa/bar/psi):
1.
Locate desired flow along bottom of chart.
2.
Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
To find Pump Air Consumption (m
#
/min or scfm) at a specific fluid flow
(ccm or oz/min) and air pressure (MPa/bar/psi):
1.
Locate desired flow along bottom of chart.
2.
Read vertical line up to intersection with selected air consumption
curve (gray). Follow right to scale to read air consumption.
235
7
0.7
14
1.4
21
2.1
28
2.8
35
3.5
42
4.2
49
4.9
cycles/min
30
90
scfm
m
#
/
min
2
4
6
0.168
0.112
0.056
56
5.6
psi
bar
MPa
0.7 MPa, 7 bar (100 psi)
air pressure
0.49 MPa, 4.9 bar (70 psi)
air pressure
0.28 MPa, 2.8 bar (40 psi)
air pressure
KEY:
Fluid Outlet Pressure – Black Curves
Air Consumption – Gray Curves
NOTE: Recommended pump speed for continuous operation: 40 cpm
Maximum recommended pump speed
(to shaded area): 60 cpm
60
63
6.3
70
7.0
0.28 MPa, 2.8 bar (40 psi)
air pressure
0.49 MPa, 4.9 bar (70 psi)
air pressure
0.7 MPa, 7 bar (100 psi)
air pressure
470
705
940
120
1
0.028
3
0.084
5
0.140
117
353
588
823
Содержание 224908
Страница 8: ...8 308302 Notes ...
Страница 15: ...15 308302 Notes ...
Страница 29: ...29 308302 Notes ...