background image

Instructions--Parts List

308118P

EN

SEVERE-DUTY, UHMWPE/PTFE PACKED

Stainless Steel Pumps

55 gallon (200 liter) drum size, with bung adapter.

For transfer and supply of solventborne and waterborne finishing materials.

For professional use only.

Important Safety Instructions

Read all warnings and instructions in this manual.

Save these instructions.

See page 2 for table of contents.

Model 224348, Series C

10:1 Ratio President

r

Pump

Model 256713, Series A

10:1 Ratio President

r

Pump (1.5 in. Female Inlet)

1800 psi (12.4 MPa, 124 bar) Maximum Fluid Working Pressure

180 psi (1.25 MPa, 12.5 bar) Maximum Air Inlet Pressure

Model 224350, Series C

5:1 Ratio Monark

r

Pump

Model 256714, Series A

5:1 Ratio Monark

r

Pump (1.5 in. Female Inlet)

900 psi (6.3 MPa, 63 bar) Maximum Fluid Working Pressure

180 psi (1.25 MPa, 12.5 bar) Maximum Air Inlet Pressure

0200A

MODEL 224348 SHOWN

2575

II 1/2 G T2
ITS03ATEX11228

2575

II 1/2 G T2
ITS03ATEX11228

Содержание 224348

Страница 1: ...r table of contents Model 224348 Series C 10 1 Ratio Presidentr Pump Model 256713 Series A 10 1 Ratio Presidentr Pump 1 5 in Female Inlet 1800 psi 12 4 MPa 124 bar Maximum Fluid Working Pressure 180 p...

Страница 2: ...y for its intended purpose If you are uncertain about usage call your Graco distributor D Do not alter or modify this equipment Use only genuine Graco parts and accessories D Check equipment daily Rep...

Страница 3: ...trigger safety operates before spraying dispensing D Lock the gun valve trigger safety when you stop spraying dispensing D Follow the Pressure Relief Procedure on page 9 whenever you are instructed to...

Страница 4: ...including solvent rags and gasoline D Electrically disconnect all equipment in the spray dispense area D Extinguish all open flames or pilot lights in the spray dispense area D Do not smoke in the sp...

Страница 5: ...and Clamp 2 Air and fluid hoses use only electrically conductive hoses with a maximum of 500 ft 150 m combined hose length to ensure grounding continuity 3 Air compressor follow manufacturer s recomme...

Страница 6: ...ump Air Regulator F Air Line Filter G Bleed Type Master Air Valve for accessories H Air Supply Hose J Fluid Drain Valve required K Fluid Filter L Fluid Supply Hose M Spray Gun N Pump Bung Adapter Y Gr...

Страница 7: ...s vent plug to prevent a vacuum from forming in the drum Air and Fluid Hoses Be sure all air and fluid hoses are properly sized and pressure rated for your system Use only electrically conductive air...

Страница 8: ...8 308118 Notes...

Страница 9: ...y to spray again If you suspect that the spray tip or hose is completely clogged or that pressure has not been fully relieved after following the steps above very slowly loosen the tip guard retaining...

Страница 10: ...ause pre mature wear of the packings and spray tip WARNING To reduce the risk of overpressurizing your system which could result in component rupture and cause serious injury never exceed the Maximum...

Страница 11: ...11 308118 Operation Fig 2 AIR MOTOR PLATE 14 0200A...

Страница 12: ...12 308118 Notes...

Страница 13: ...sup ply Clear increase air supply Insufficient air pressure closed or clogged air valves etc Open clean Exhausted fluid supply Refill purge all air from pump and fluid lines Clogged fluid line valves...

Страница 14: ...acement rod 1 Orient the pump s fluid outlet R to the air motor s air inlet S as was noted in step 2 under Disconnecting the Displacement Pump Position the displace ment pump 101 on the tie rods 102 S...

Страница 15: ...ons on how to verify correct orientation see NOTE in step 7 on page 16 5 Loosen the packing nut 14 then pull the dis placement rod 1 and connecting rod 8 out the bottom of the outlet housing 5 6 Secur...

Страница 16: ...ealant to the male threads of the adapter 10 Screw the piston mounting stud 13 onto the connecting rod adapter 10 and torque to 50 70 ft lb 68 95 NSm 5 Place the flats of the displacement rod 1 in a v...

Страница 17: ...2 3 25 3 4 LIPS OF V PACKINGS MUST FACE DOWN 5 SEE DETAIL B 5 6 7 15 8 1 9 11 12 17 18 19 21 16 27 13 10 20 1 2 Apply sealant and torque to 50 70 ft lb 68 95 NSm 1 1 1 Apply thread lubricant 2 2 2 DET...

Страница 18: ...See pages 20 and 21 for parts 1 102 166237 ROD tie stainless steel 3 5 89 mm shoulder to shoulder 3 105 156082 SEAL o ring nitrile rubber 1 106 207352 AIR MOTOR See manual 306982 for parts 1 107 15825...

Страница 19: ...DISPLACEMENT PUMP ASSY 1 5 in female inlet See pages 20 and 21 for parts 1 102 24B189 ROD tie stainless steel 3 5 89 mm shoulder to shoulder 3 105 156082 SEAL o ring nitrile rubber 1 106 205997 AIR MO...

Страница 20: ...acement Pump Model 256712 Series A Severe Duty Stainless Steel Displacement Pump 1 5 in Female Inlet Includes items 1 34 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 25 26 28 29 30 31 3 13 27 30...

Страница 21: ...6 V PACKING throat PTFE 2 26 176634 WASHER piston stainless steel 1 27 186993 STUD piston stainless steel 1 28 186990 GLAND piston male stainless steel 1 29 176635 V PACKING piston PTFE 2 30 176638 V...

Страница 22: ...Fluid flow at 60 cpm 3 gallon 11 4 liters Recommended speed for optimum pump life 15 25 cycles min 0 75 1 25 gpm 2 84 to 4 73 liters min Air consumption approx 15 scfm 0 42 m3 min at 1 gpm 3 8 liters...

Страница 23: ...a 12 5 bar 180 psi air pressure B 0 7 MPa 7 bar 100 psi air pressure C 0 49 MPa 4 9 bar 70 psi air pressure D 0 28 MPa 2 8 bar 40 psi air pressure 1 4 14 D Air Consumption Chart 0 20 40 60 80 100 0 1...

Страница 24: ...flow at 60 cpm 2 5 gallon 9 46 liters Recommended speed for optimum pump life 15 25 cycles min 0 63 1 04 gpm 2 38 to 3 94 liters min Air consumption approx 8 2 scfm 0 23 m3 min at 1 gpm 3 8 liters mi...

Страница 25: ...0 7 MPa 7 bar 100 psi air pressure C 0 49 MPa 4 9 bar 70 psi air pressure D 0 28 MPa 2 8 bar 40 psi air pressure 1 4 14 D Air Consumption Chart 0 8 16 24 32 40 0 1 2 3 4 5 PUMP DELIVERY Test Fluid No...

Страница 26: ...0 in 42 68 in 1379 mm 295 mm 1084 mm 256714 55 16 in 11 60 in 43 56 in 1401 mm 295 mm 1106 mm Model 224348 Shown A C Model 224348 3 8 npsm f Model 224350 3 8 npt f AIR INLET 3 4 npt f FLUID OUTLET B 0...

Страница 27: ...27 308118 Notes...

Страница 28: ...t sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale Graco mak...

Отзывы: