background image

307879        5

Installation

Grounding

WARNING

FIRE AND EXPLOSION HAZARD
Before operating, ground the system as
explained below. Also read the section
FIRE AND EXPLOSION HAZARD on
page 4.

Static electricity is created by the flow of fluid through
the pump and hose. If the pump is not properly
grounded, sparking may occur, and the system may
become hazardous. Sparking may also occur when
plugging in or unplugging a power supply cord. Sparks
can ignite fumes from solvents, dust particles and
other flammable substances, whether you are
operating indoors or outdoors, and can cause a fire or
explosion and serious bodily injury and property
damage.

To reduce the risk of static sparking, ground all the
dispensing equipment used or located in the work
area. Check you local electrical code for detailed
grounding instructions for your are and type of
equipment. Be sure to ground all of this equipment.

D

Pump or sprayer:  If using an electric sprayer, plug
the power supply cord or extension cord, each
equipped with an undamaged three-prong plug, into
a properly grounded outlet. Do not use an adapter.
All extension cords must have three wires and be
rated for 15 amps. If using another type of sprayer
or pump, ground it by connecting a grounding wire
(12 ga minimum) from the pump or sprayer’s
grounding lug to a true earth ground.

D

Air compressor or hydraulic power supply:  Follow
the local code.

D

Fluid hoses:  Use only electrically conductive hoses
with a maximum of 500 feet (150 m) combined
hose length to ensure grounding continuity.

D

Spray gun:  Obtain grounding through connection to
a properly grounded fluid hose and sprayer or
pump.

D

Supply container:  Follow the local code.

D

Object being sprayed:  Follow the local code.

D

All solvent pails used when flushing:  Follow the
local code. Use only metal pails, which are
conductive. Do not place the pail on a
non-conductive surface, such as paper or
cardboard, which interrupts the grounding
continuity.

D

To maintain grounding continuity when flushing or
relieving pressure
, always hold a metal part of the
gun firmly to the side of a grounded metal pail, then
trigger the gun.

To ground the pump, loosen the grounding lug
locknut (W) and washer (X). Insert one end of a
12 ga (1.5 mm

2

) minimum ground wire (Y) into the

slot (Z) in the lug, and tighten the locknut securely.
Connect the other end of the wire to a true earth
ground. To order a ground wire and clamp, order
Part No.  222011.

X

W

Y

Z

Содержание 222077

Страница 1: ...filled undercoating materials Model No Size Type Dis pense Kit Cover 222077 35 lb portable X X 226342 120 lb rollaround X X 226269 400 lb stationary X X WARNING These systems are designed to be used only in pumping petroleum based undercoating materials Any other use of the system can cause unsafe operating conditions and result in component rupture fire or explosion which can cause serious bodily...

Страница 2: ...n 7 Parts Drawings and Lists Model 222077 35 lb Pail Size Unit 9 Dispense Kit 222079 9 Model 226342 120 lb Drum Size Unit with Dolly 10 Model 226269 400 lb Stationary Drum Size Unit 11 Dispense Kit 222082 11 Accessories 12 Graco Warranty 14 Graco Phone Number 14 ...

Страница 3: ...id this is not an air spray system D Always have the tip guard and the trigger guard on the gun when spraying D Be sure the gun trigger safety operates before spraying D Lock the gun valve trigger safety when you stop spraying D Follow the Pressure Relief Procedure on page 7 whenever you are instructed to relieve pres sure stop spraying clean check or service the equipment and install or clean the...

Страница 4: ...e operating the equipment D Use the equipment only for its intended purpose If you are uncertain about usage call your Graco distributor D Do not alter or modify this equipment Use only genuine Graco parts and accessories D Check the equipment daily Repair or replace worn or damaged parts immediately D The maximum working pressure of the 15 1 Ratio Fire Ball pumps is 2250 psi 16 MPa 157 bar at a m...

Страница 5: ...ds must have three wires and be rated for 15 amps If using another type of sprayer or pump ground it by connecting a grounding wire 12 ga minimum from the pump or sprayer s grounding lug to a true earth ground D Air compressor or hydraulic power supply Follow the local code D Fluid hoses Use only electrically conductive hoses with a maximum of 500 feet 150 m combined hose length to ensure groundin...

Страница 6: ... air to the pump if the pump accelerates beyond the pre adjusted setting A pump that runs too fast can be seriously damaged 2 Install an air line lubricator F for automatic air motor lubrication 3 Install the air regulator C to control pump speed and pressure 4 On the main air supply line from the compressor install an air line filter E to remove harmful dirt and contaminants from your compressed ...

Страница 7: ...ump and open any air bleed valves in the system 3 Disengage the gun safety latch 4 Hold a metal part of the gun firmly to the side of a grounded metal pail and trigger the gun to relieve pressure 5 Engage the gun safety latch 6 Open the fluid drain valve and have a container ready to catch the drainage 7 Leave the drain valve open until you are ready to use the system again If you suspect that the...

Страница 8: ...ponent connected to a particular pump To determine the fluid output pressure using the air regulator reading multiply the ratio of the pump by the air pressure shown on the regulator gauge For example 10 1 ratio x 100 psi air 1000 psi fluid output 10 1 ratio x 7 bar air 70 bar fluid output 10 1 ratio x 0 7 MPa air 7 MPa fluid output Limit the air to the pump so that no air line or fluid line compo...

Страница 9: ...22 SCAPSCREW 2 Dispense Kit 222079 Ref No Part No Description Qty 101 109075 AIR REGULATOR See 307204 for parts 1 102 208536 COUPLER quick disconnect 1 103 204940 SWIVEL See 306861 for parts 1 106 156971 NIPPLE 1 4 npt 1 107 109165 HOSE fluid cpld 1 108 210890 SPRAY GUN See 307260 for parts 1 109 156849 NIPPLE 3 8 npt 1 110 104984 TEE pipe 1 4 npt 1 111 210657 BALL VALVE See 306861 for parts 1 112...

Страница 10: ... See 306531 for parts 1 2 222079 DISPENSE KIT See Parts List on page 9 1 3 204574 COVER See 306345 for parts 1 4 204144 BASE dolly Includes items 4a to 4d 1 4a 100023 WASHER flat 5 16 1 4b 100307 NUT full hex 3 8 16 1 4c 101851 CASTER wheel 2 1 2 dia 4 4d 102971 BOLT carriage 3 8 16 x 3 1 4e 205419 CLAMP dolly 1 1 3 4e 4d 4a 4b 4c 2 ...

Страница 11: ... No Description Qty 101 109075 AIR REGULATOR See 307204 for parts 1 102 208536 COUPLER quick disconnect 1 103 204940 SWIVEL See 306861 for parts 1 106 156971 NIPPLE 1 4 npt 1 107 109167 HOSE fluid cpld 1 108 210890 SPRAY GUN See 307260 for parts 1 109 156849 NIPPLE 3 8 npt 1 110 104984 TEE pipe 1 4 npt 1 111 210657 BALL VALVE See 306861 for parts 1 112 100840 ELBOW street 1 4 npt 1 113 169971 FITT...

Страница 12: ...Clamp Wire 222011 12 ga 25 ft 7 6 m wire Air Line Filter 250 psi 1 7 MPa 17 4 bar Maximum Working Pressure 106148 3 8 npt 106149 1 2 npt Bleed type Master Air Valve 107142 300 psi 2 1 MPa 21 bar Maximum Working Pressure Relieves air trapped in the air line between the pump air inlet and this valve when closed 1 2 npt Air Regulator 300 psi 2 1 MPa 21 bar Maximum Working Pressure 109075 3 8 npt 1042...

Страница 13: ...307879 13 Notes ...

Страница 14: ...h above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale GRACO MAKES NO WARRANTY AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILIT...

Отзывы: