6
307882
Setup
Fig 2
KEY
A
Pump Ground Wire
B
Main Air Supply Line
C
Air Filter
D
Air Line Lubricator
E
Pump Runaway Valve
F
Bleed-type Master Air Valve
101
Hose
102
Dispense Valve
103
Quick-disconnect Coupler
104
Quick-disconnect Nipple
105
Regulator
106
Nipple
107
Z-swivel
E
105
B
D
C
A
Detail A
103
F
TI1015
102
103
104
105
106
1
101
3
107
For All Models
Assemble the air and fluid lines as shown in Fig 2.
For Model 222078
Secure pump to cover (3) with the screws and lo-
ckwashers provided. Position the assembly on an
opened 35 lb pail. Tighten the thumbscrews firmly.
For Model 220170
Secure cover (3) to opened fluid container with the
thumbscrews provided. Insert the pump through the hole
in the cover and lower it into the container. It is not neces-
sary to bolt the pump to the cover.
For Model 220171
Set cover (3) on open drum. Thumbscrews are not re-
quired. Insert the pump through the hole in the cover and
lower it into the drum. It is not necessary to bolt the pump
to the cover.
Air Line Accessories
Install the air line accessories in the order shown in
Fig 2. Detail A.
1.
Install a bleed-type master air valve (F) to isolate the
accessories for service.
2.
Install an air line filter (C) to remove harmful dirt and
contaminants from your compressed air supply.
3.
Install an air line lubricator (D) for automatic air motor
lubrication.
4.
Install a pump runaway valve (E) to shut off the air to
the pump if the pump accelerates beyond the pre-
adjusted setting. A pump which runs too fast can be
seriously damaged.
5.
Attach the quick disconnect coupler (103) to the air
supply hose.
CAUTION
Avoid hanging the air accessories directly on the pump
air inlet. The fittings are not strong enough to support
the accessories and may cause one or more to break.
If accessories must be installed directly on the pump,
provide a bracket on which to mount the accessories.
Содержание 220170
Страница 11: ...307882 11 Notes...