background image

Warnings 

4

306565K

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system 
component. See Technical Specifications in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. SeTechnical 
Specifications
 
in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For 
complete information about your material, request Safety Data Sheets (SDSs) from distributor or 
retailer.

Do not leave the work area while equipment is energized or under pressure. 

Turn off all equipment and follow thPressure Relief Procedure when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine 
manufacturer’s replacement parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and create 
safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or 
swallowed.

Read Safety Data Sheets (SDSs) to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

PERSONAL PROTECTIVE EQUIPMENT 

Wear appropriate protective equipment when in the work area to help prevent serious injury, including 
eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not 
limited to:

Protective eyewear, and hearing protection. 

Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

WARNING

Содержание 204536

Страница 1: ...s For professional use only 100 psi 0 7 MPa 7 bar Maximum Working Pressure See page 2 for model information including maximum working pressure and approvals Important Safety Instructions Read all warn...

Страница 2: ...4536 224571 224572 Stainless Steel Agitators 12 Dimensions 14 Technical Specifications 15 California Proposition 65 15 Graco Standard Warranty 16 Models Agency Approvals Model Maximum Working Pressure...

Страница 3: ...and gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggeri...

Страница 4: ...y approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for...

Страница 5: ...3 8 npt f 208392 3 8 npt f x 1 4 npt m 208393 3 8 npt m x 3 8 npt m Install an air line filter AF to remove harmful dirt and moisture from the air supply To order an air line filter order part number...

Страница 6: ...5 onto the agitator shaft 12 or 13 Apply anaerobic sealant and torque nut 5 See Parts page 12 Model 204536 Screw the straight tube fitting 14a into the needle valve s 2 1 8 npt inlet See FIG 2 Screw...

Страница 7: ...See FIG 3 Secure the ground wire terminal C to the agitator with the screw and lockwasher Connect the other end of the ground wire to a true earth ground To order a ground wire assembly order part num...

Страница 8: ...repeating the procedure described above Operating the Agitator Operate the agitator continuously while supplying paints or other fluids to the system Use the needle valve 2 to regulate the agitator sp...

Страница 9: ...is compatible with the spray material and the surfaces being cleaned Additionally extra precautions need to be taken if using lower conductive materials 1000 pS m such as Avoid stirring mixing at hig...

Страница 10: ...present in the motor chamber an experienced mechanic may remove the end plate opposite the drive shaft end New vanes should have the edges with cut corners or the notched edges if the vanes are rever...

Страница 11: ...Service 306565K 11...

Страница 12: ...Includes items 2 to 12 MODEL 204536 ONLY 14b 14c Ref 14 Tube Assembly Includes items 14a to 14c 14a 15 MODEL 204536 ONLY Ref 15 Hose 1 Apply medium grade sealant to external threads 2 Press fit 7 9 2...

Страница 13: ...164700 BODY valve 1 2d 166531 WASHER nylon 1 2e KNOB adjustment 1 2f 166532 NUT packing 1 3 110272 SET SCREW schd cup pt 1 420 x 1 4 SST 2 4 103975 LOCKWASHER spring 3 8 in SST1 1 5 110271 NUT hex cap...

Страница 14: ...Dimensions 14 306565K Dimensions 3 12 in 80 mm 3 12 in 80 mm 13 25 in 337 mm 17 25 in 433 mm MODELS 204536 222695 Agitators for 5 gallon pail MODEL 224572 Agitator for 10 gallon pail...

Страница 15: ...a 7 bar 800 RPM normal load Sound pressure level Sound power level 65 3 dBa 78 6 dBa Noise level at 100 psi 0 7 MPa 7 bar max RPM no load Pressure level Power level 87 3 dBa 100 7 dBa Tested to CAGI P...

Страница 16: ...at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIM...

Отзывы: