Installation
3A6976C
7
4.
Assemble the sensor.
a.
Slip the o-ring (3) onto the sensor (1). See F
b.
Screw the sensor bushing (2) onto the sensor
5.
Screw the sensor assembly into the pump. Use
thread sealant as needed.
6.
Connect the sensors to your monitoring device
according to your device’s instructions. See F
for sensor wiring connections. See Technical Data
for electrical specifications.
Leak Sensor Kit 17Z666
1.
To install the sensors, first disconnect power to the
control box.
2.
Relieve pump pressure. Follow the Pressure Relief
Procedure in your pump manual.
3.
Mount the leak detector control box in a convenient
location.
4.
Remove plugs from the pump air covers, if plugs are
present. See F
5.
Screw the sensors into the pump. Use thread
sealant, as needed. See F
IG
. 5.
F
IG
. 3. ATEX-Certified Sensor Assembly
F
IG
. 4. Sensor Wiring Connections
1
2
3
Electric Shock
To avoid potential injury from electric shock, shut off
power to the control box before installing the sensors
or servicing the leak detector system.
Pressure Relief
Your diaphragm pump stays pressurized until
pressure is relieved manually. To help prevent
serious injury from pressurized fluid, such as
splashing in the eyes or on skin, follow the Pressure
Relief Procedure when you stop pumping and before
you install the leak detector sensors. Refer to your
pump manual for the correct Pressure Relief
Procedure.
F
IG
. 5. Typical Control Box and Sensor Installation
Control Box
Sensors