Component Identification

3A5591D

7

Central Body

Key:

H

Central body (with lance)

J

Packing set material inlet

K

Packing set material return

L

Gasket

M

Locating pins

N

Valve needle guide

O

Valve needle packing set

The central body 

connects material, air and electrical 

signals from the solenoid valves. Two parallel channels 
supply material up to the nozzle head. A third channel is 
provided for the material return flow back to the swivel 
housing.

A needle guide (N) is located at the front end of the cen-
tral body (H) to align the needle valves with the valve 
seats in the nozzle head. The nozzle head gasket (L) 
seals between the material supply and the nozzle head 
(D). The two nozzle head locating pins (M) ensure that 
the nozzle head is always mounted in the correct posi-
tion. The valve needles packing set (O) seals off the 
valve needles from material and air pressure.

Channel arrangements in the central body:

Blue:

 Product in

Red:

 Return (if unit is equipped with circulation)

Green:

 Signals from the solenoid valves

F

IG

. 2

H

J

J

K

L

M

N

O

F

IG

. 3: Product Flow

Air Signals

Product In

Return

Product In

Содержание 17V558

Страница 1: ...g applications For professional use only Not approved for use in European explosive atmosphere locations See page 2 for model information Important Safety Instructions Read all warnings and instructio...

Страница 2: ...anty 28 Graco Information 28 Models Related Manuals Part No Model Name Description Applied Material Quantity Sensor Types Wetted Parts Material 17V558 G 3S Dispenser 3D 1 N A Aluminum Alloy 17V559 G 3...

Страница 3: ...diately EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury Do not operate the unit when fatigued or under the influence of drugs or alcohol Do not exceed the maximum working pressure or...

Страница 4: ...s may contain chemicals that can react with aluminum Contact your material supplier for compatibility BURN HAZARD Equipment surfaces and fluid that is heated can become very hot during operation To av...

Страница 5: ...erbody Seal ing UBS Liquid applied sound deadening LASD and seam sealing The Graco 3D gun is designed to handle most types of single component adhesives and sealants with medium to high viscosity The...

Страница 6: ...tion 6 3A5591D Component Identification Main Assemblies Key A Central body assembly B Swivel chamber C Connection housing D Nozzle head assembly E Cylinder assembly F Material valve needle G Lock ring...

Страница 7: ...A needle guide N is located at the front end of the cen tral body H to align the needle valves with the valve seats in the nozzle head The nozzle head gasket L seals between the material supply and t...

Страница 8: ...en the two channels If the applicator is used in an application without mate rial circulation the two material channels are joined to one supplying material through all three channels in the central b...

Страница 9: ...s to the applicator The connections for material supply AW and return AV are placed in the upper connection piece The connections are internal 3 8 BSP One or two con nectors for electrical signals are...

Страница 10: ...es sure that the connections follow the motion of axis 5 Only the central body follows the motion of axis 6 NOTE See your Repair Parts manual for more informa tion on which swivel locking bracket shou...

Страница 11: ...e head BB and the nozzle cap BA The nozzle head base part includes the valve seats for the material valve and mounted to the central body with three M4 screws BF The nozzle cap is fixed to the base pa...

Страница 12: ...g CH Threaded needle CJ Piston CK O ring CL Set screw ISO 4029 M4 x 5 CM Guide ring The cylinder assembly contains the cylinder housing CB and three pneumatically operated pistons CJ that actuate the...

Страница 13: ...ws The mounting flange is the interface between the applicator and the sixth axis of the robot Consequently the design of the mounting flange is robot dependent The flange EA is fixed to the robot usi...

Страница 14: ...crews Begin the installation by mounting the mounting flange see page 13 on the sixth axis of the robot using the six M6x16 screws with extra low heads When the flange is fixed on the robot the applic...

Страница 15: ...oint Return If circulation was not selected the return connection is plugged If dual mate rials are supplied both connections are inlets no return possible After completion of the installation of hose...

Страница 16: ...urn hose Always use two wrenches when loos ening the high pressure hose connection 3 Disconnect the air hose 4 Unplug the electrical connectors by pulling the cable connectors backwards from the cable...

Страница 17: ...this unscrew the M6 hex button head screw BE Then remove the nozzle cap with nozzles BC Take care not to lose the nozzle gaskets BD 2 Unscrew the three hex head screws Allen screws that fixes the noz...

Страница 18: ...ction housing can now be separated 6 All internal parts can now be removed from the swivel chamber special tool 17V862 recom mended If need be also the solenoid valves can be detached 7 All internal g...

Страница 19: ...nd Reassembly of Applicator 3A5591D 19 8 The connection housing can also be further disman tled if o rings or sensors if so equipped need to be replaced FIG 24 AA AB AC AD AE AF AG AH AJ AK AL AM AN A...

Страница 20: ...so three needle packing located in the cylinder housing The material valve needles gasket and guide can now be removed from the central body 12 With the needles removed pull out the needle pack ing sp...

Страница 21: ...icant and thread locking compound should also be available 1 Insert needle packings and guides with the special tools 17V860 and 17V861 Note that there are double packings on the side facing the cylin...

Страница 22: ...rrectly seated in the piston Apply a small amount of thread sealing compound on the screws locking the needle in position Tighten the screws Check that the pistons needles can be moved freely albeit w...

Страница 23: ...housing Avoid the sharp edges shown in FIG 38 b Press down the seal with the tool c Note the difference depending on the number of seals check spare parts list for exact version d Press down the last...

Страница 24: ...is recommended to do a function test before the applicator is returned to production The extent of the test is dependent on the degree of maintenance performed on the applicator and the avail able te...

Страница 25: ...or See Applicator Removal on page 16 2 Clean all parts thoroughly and make sure no parts are damaged or worn out 3 Replace all parts included in the service kits See the appropriate Parts manual for a...

Страница 26: ...Dimensions 26 3A5591D Dimensions 5 9 in 149 6 mm 1 2 in 30 mm 2 4 in 61 6 mm 4 5 in 115 mm 1 6 in 40 mm 1 5 in 38 mm 11 9 in 302 1 mm 1 1 in 28 mm X 17 4 in 442 mm X Robot Flange Dimensions...

Страница 27: ...8 17V559 17V560 17V561 Male 3 8 BSP connector 17V562 17V563 N A 17V564 17V565 Plug Torque Requirement M3 Screw 12 in lb 1 35 N m M4 Screw 29 2 in lb 3 3 N m M5 Screw 57 5 in lb 6 5 N m M6 Screw 98 2 i...

Страница 28: ...n material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRA...

Отзывы: