Cleanup
20
3A5097C
5.
It is recommended to dispose of the used
FlexLiner (4) and install a new one. If
reusing, clean by wiping all excess fluid
from FlexLiner (4).
6.
Wipe excess fluid from cover (2) and ring
(1) of FlexLiner System.
7.
Fill the FlexLiner (4) approximately
half-full with cleaning fluid (warm water
or appropriate solvent).
8.
Remove and clean material strainer (3)
by flushing with cleaning fluid. Re-install
material strainer (3).
9.
Install cover (2) and ring (1) onto cup (5).
NOTICE
Dispose of FlexLiner, cleaning materials,
and unused fluid according to local
regulations. Refer to Safety Data Sheet
(SDS) of fluids used.
ti30776a
ti30900a
ti30777a
ti30680a
Содержание 17P483