background image

Warnings 

4

332156D

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, 

follow the 

Pressure Relief Procedure

 and disconnect all power sources.

SUCTION HAZARD 

Powerful suction could cause serious injury.

Never place hands near the pump fluid inlet when pump is operating or pressurized. 

CARBON MONOXIDE HAZARD

Exhaust contains poisonous carbon monoxide, which is colorless and odorless. Breathing carbon 

monoxide can cause death.

Do not operate in an enclosed area.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or 

swallowed.

Read MSDSs to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

BATTERY SAFETY 

The battery may leak, explode, cause burns, or cause an explosion if mishandled.

• Only use the battery type specified for use with the equipment. See 

Technical Data

• Battery maintenance must only be performed or supervised by personnel knowledgeable of 

batteries and the required precautions. Keep unauthorized personnel away from battery. 

• Do not dispose of battery in fire. The battery is capable of exploding. 

• Follow local ordinances and/or regulations for disposal. 

• Do not open or mutilate the battery. Released electrolyte has been known to be harmful to the skin 

and eyes and to be toxic. 

• Remove watches, rings, or other metal objects.

• Only use tools with insulated handles. Do not lay tools or metal parts on top of battery. 

BURN HAZARD 

Equipment surfaces and fluids that are heated can become very hot during operation. To avoid severe 

burns:

Do not touch hot fluid or equipment.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including 

eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is 

not limited to:

Protective eyewear, and hearing protection. 

Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

CALIFORNIA PROPOSITION 65 

The engine exhaust from this product contains a chemical known to the State of California to cause 

cancer, birth defects or other reproductive harm.
This product contains a chemical known to the State of California to cause cancer, birth defects or other

reproductive harm. Wash hands after handling.

WARNING

WARNING

WARNING

WARNING

Содержание 16U277

Страница 1: ...Bare Vanguard 1000 psi 6 9 MPa 69 bar 16U278 16U278V GH2570es Bare Vanguard 2500 psi 17 2 MPa 172 bar 16U279 16U279V GH733es Bare Vanguard 4000 psi 27 6 MPa 276 bar 16U280 16U280V GH5040es Bare Vangua...

Страница 2: ...t Identification 5 Lift Instructions 6 Pressure Relief Procedure 7 Grounding 7 Setup 8 Startup 9 SwitchTip and Guard Assembly 11 Clearing Tip Clogs 11 Spraying 12 Cleanup 13 Troubleshooting 15 Technic...

Страница 3: ...gering into pail Do not use pail liners unless they are anti static or conductive Stop operation immediately if static sparking occurs or you feel a shock Do not use equipment until you identify and c...

Страница 4: ...or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from battery Do not dispose of battery in fire The battery is capable of exploding F...

Страница 5: ...n 1 Engine Controls 2 Ignition 3 Engine ON OFF Switch Pull Start units 4 Lift Location 5 Suction Tube Holder 6 Pressure Control 7 Lock Ring 8 Serial Number ID Label 9 Hydraulic Pump Valve 10 Hydraulic...

Страница 6: ...ing are rated to support weight of sprayer 500 lbs 227 kg 4 Do not lift unit with only one strap secured across pump This could put stress on frame and damage pump To avoid injury always use designate...

Страница 7: ...ve pressure 4 Rotate handle counter clockwise to open prime valve Grounding This equipment stays pressurized until pressure is manually relieved To help prevent serious injury from pressurized fluid s...

Страница 8: ...store 6 Check engine oil level Add SAE 10W 30 summer or 5W 20 winter if necessary 7 Fill fuel tank 8 Check hydraulic oil level Component ID page 5 Add only Graco Hydraulic Oil ISO 46 169236 5 gallon...

Страница 9: ...ump valve OFF 5 Start engine a Move fuel valve to open b Move choke to closed c Set throttle to fast d For electric start models Rotate key to start For pull start models Set engine switch to ON Pull...

Страница 10: ...etal flushing pail Trigger gun and increase fluid pressure slowly until pump runs smoothly 11 Inspect fittings for leaks Do not stop leaks with your hand or a rag If leaks occur turn sprayer OFF immed...

Страница 11: ...er safety ON Rotate SwitchTip Take trigger safety OFF and trigger gun to clear the clog 2 Put trigger safety ON return SwitchTip to original position take trigger safety OFF and continue spraying 3 If...

Страница 12: ...rt hydraulic motor stroking and allow fluid to circulate for 15 seconds turn pressure down 3 Turn spray gun trigger safety OFF 4 Adjust pressure to desired setting Begin spraying 5 Rotate Lock Ring cl...

Страница 13: ...et pump valve ON Rotate handle clockwise to close prime valve 8 Hold gun against paint pail Take trigger safety OFF Turn pressure control up until motor begins to drive pump 9 Trigger gun until flushi...

Страница 14: ...il to purge fluid from hose 15 Rotate handle counter clockwise to open prime valve 16 If pump includes filter install filter into filter bowl Make sure plastic center tube is tightened securely Hand t...

Страница 15: ...rod Service pump See manuals 308043 311825 311762 Hydraulic motor not shifting Set pump valve OFF Turn pressure down Turn engine OFF Pry rod up or down until hydraulic motor shifts See manual 332157 D...

Страница 16: ...larger diameter or shorter hose The sprayer overheats Paint buildup on hydraulic components Clean Oil level is low Fill with oil Spitting from gun Air in fluid pump or hose Check for loose connections...

Страница 17: ...mm 5 guns 029 in 0 71 mm 6 guns 026 in 0 66 mm Fluid Inlet 1 25 in npt m 3 2 cm npt f Fluid Outlet with fitting as shipped 0 75 in nps f swivel 1 9 cm npsm Fluid Outlet Pump 1 0 in npt f 2 5 cm npt f...

Страница 18: ...guns 031 in 0 79 mm 6 guns 028 in 0 71 mm Fluid Inlet 1 25 in npt m 3 2 cm npt f Fluid Outlet with fitting as shipped 0 75 in nps f swivel 1 9 cm npsm Fluid Outlet Pump 1 0 in npt f 2 5 cm npt f Dimen...

Страница 19: ...guns n a n a 6 guns n a n a Fluid Inlet 2 in npt f 5 cm npt f Fluid Outlet with fitting as shipped 0 75 in nps f swivel 1 9 cm npsm Fluid Outlet Pump 1 5 in npt f 3 8 cm npt f Dimensions Weight 473 l...

Страница 20: ...5 cm npt f Fluid Outlet with fitting as shipped 0 75 in nps f swivel 1 9 cm npsm Fluid Outlet Pump 1 5 in npt m 3 8 cm npt m Dimensions Weight 471 lb 214 kg Height 49 in 124 cm Width 28 in 71 cm Lengt...

Страница 21: ...2 cm npt f Fluid Outlet Pump 0 5 in npt f 1 8 cm npt f Fluid Outlet with fitting as shipped 0 5 in npt m 1 8 cm npt m Dimensions Weight 438 lb 199 kg Height 49 in 124 cm Width 28 in 71 cm Length 43 i...

Страница 22: ...INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set fort...

Страница 23: ...Graco Standard Warranty 332156D 23...

Страница 24: ...notice For patent information see www graco com patents Original instructions This manual contains English MM 332156 Graco Headquarters Minneapolis International Offices Belgium China Japan Korea GRA...

Отзывы: