15W034 Beacon Tower Kit Installation
2
313542F
15W034 Beacon Tower Kit
Installation
NOTE: Kit 15W034 is for ProMix 2KS manual systems.
1.
Feed wires through the hole in adapter (A) and
secure the adapter to beacon (1) with set screws.
2.
Remove the 3/4 in. (19 mm) knockout on top of the
EasyKey. Feed the wires through the hole and
secure the beacon (1) with the jam nut (N) and
washer on the inside of the box. See F
IG
. 1.
3.
Install the din rail (7) with two screws (8). Install the
header (5) on the din rail and connect the cable (4)
to J5 on the EasyKey display board. See F
4.
Connect yellow and gray wires from beacon to the
power terminal. See F
IG
. 2.
5.
Connect orange, brown, and red wires to header (5)
pins 3, 4, and 5. See F
IG
. 6 on page 6.
6.
To enable the optional audible alarm, connect pur-
ple wire to pin 3 on header (5). See F
IG
. 6 on page
6. When enabled, it will sound for all system alarms.
7.
When beacon wiring is completed, insulate the end
of each unused lead wire with insulation tape.
Beacon Signals
NOTE: See the ProMix 2KS operation manual for details
of the specific alarms.
F
IG
. 1: Install Beacon on EasyKey
™
TI14040b
1
N
A
F
IG
. 2: Power Terminal Connections
Flashing
Signal/
Audible
Description
Amber
A system warning is active; verify alarm.
Red
A potlife alarm exists.
System goes to Standby.
Green
Not used.
Audible
A system warning is active; verify alarm.
INPUT A
C
OUTPUT DC
DC
OK
+
-
-
N (-)
NC
NC
L (+)
TI14041a
Gray (+24V)
Yellow
(Common)