background image

Installation 

6

3A8569A

Installation

Grounding

Pump

NOTE: The reference numbers in the following section 
refer to 

Parts

, page 12.

NOTE: Pipe/thread sealant is user supplied, do not use 
the PVC cement supplied with the product.

The oil transfer pumps are positive displacement 
pumps. The motors are drip proof rated and have sealed 
bearings and require minimal maintenance. All models 
come with hose, nozzle, 34 in. (864 mm) suction tube 
assembly, and bung adapter.

Mount Pump on Drum

1.

Install the bung adapter (14) in the drum bung and 
tighten.

2.

Assemble the suction tube sections (18) by applying 
PVC cement (21) to the inside diameter of the PVC 
couplers (19, 20). Make sure that the PVC cement is 
applied to the complete inside diameter and slide 
the pipe sections into the coupler with a twisting 
motion.

3.

Apply pipe sealant (not supplied, do not use the 
supplied PVC cement) to the threaded end of the 
suction tube, then screw the tube into the pump inlet 
port, making sure that the tube is tight.

4.

Insert the suction tube attached to the pump 
through the bung adapter, and lower the pump onto 
the bung adapter. Position the pump, as desired, 

then tighten the swivel nut (23) to the bung adapter 
(14).

Mount Hose and Nozzle

1.

Before connecting the hose to the pump, pour 8 z. 
(0.24 l) of oil into the pump outlet port so that the 
pump does not run dry during the initial startup.

2.

Apply pipe sealant to the male threads of the elbow 
(12), then secure the elbow into the outlet port.

3.

Apply pipe sealant to one end of the hose assembly 
(17), then twist the hose end into the elbow.

4.

Apply pipe sealant to the other end of the hose 
assembly (17).

5.

Apply thread sealant onto the nozzle (15) end that 
connects to the ball valve (16).

6.

Fasten the ball valve and nozzle (15, 16) onto the 
hose assembly, positioning the nozzle (15) down for 
dispensing.

Electrical Installation

12 V DC

The 12 VDC model is not shipped with a power cord 
since the installation will determine the length of the 
power cord.

1.

Verify the on/off switch is in the OFF position.

2.

Remove the wiring junction box cover by removing 
the four (4) screws.

3.

Bring the 12 VDC, 10 AWG supply wire through the 
junction box strain relief. 

4.

Tighten the strain relief.

5.

Connect the motor red wire (+) and the motor black 
wire (-) to the supply wires using nuts (user 
supplied).

6.

Reattach the wiring junction box cover with the four 
(4) screws.

The equipment must be grounded to reduce the risk 
of static sparking. Static sparking can cause fumes to 
ignite or explode. Grounding provides an escape wire 
for the electric current.

All electrical wiring must be done by a qualified 
electrician and comply with all local codes and 
regulations.

Содержание 12 VDC EGP

Страница 1: ...ils hydraulic fluid and antifreeze Do not use to pump water For professional use only 25T819 Electric Gear Pump 3 8 gpm 14 4 lpm 65 psi 0 45 MPa 4 5 bar Maximum Working Pressure Important Safety Instr...

Страница 2: ...ozzle 6 Electrical Installation 12 V DC 6 Operation 7 Pressure Relief Procedure 7 Duty Cycle 7 Pump Start Up 7 Recycling and Disposal 8 End of Product Life 8 Troubleshooting 9 Parts 12 Kits and Access...

Страница 3: ...Equipment surfaces and fluid that is heated can become very hot during operation To avoid severe burns Do not touch hot fluid or equipment EQUIPMENT MISUSE HAZARD Misuse can cause death or serious in...

Страница 4: ...ctions before operating the equipment Check hoses tubes and couplings daily Replace worn or damaged parts immediately PERSONAL PROTECTIVE EQUIPMENT Wear appropriate protective equipment when in the wo...

Страница 5: ...Typical Installation 3A8569A 5 Typical Installation FIG 1 Typical Installation...

Страница 6: ...g the hose to the pump pour 8 z 0 24 l of oil into the pump outlet port so that the pump does not run dry during the initial startup 2 Apply pipe sealant to the male threads of the elbow 12 then secur...

Страница 7: ...If the flow is blocked the fluid will bypass within the pump 3 Insert the nozzle 15 into the container and open the ball valve 16 to dispense fluid 4 Turn the switch to the OFF position immediately a...

Страница 8: ...nd recycle it in a responsible manner Perform the Pressure Relief Procedure Drain and dispose of fluids according to applicable regulations Refer to the material manufacturer s Safety Data Sheet Remov...

Страница 9: ...l is low Refill or replace the drum There is an air leak in the suction tube Inspect all joints in the suction tube making sure that all threaded joints have sealant applied properly Fill pump outlet...

Страница 10: ...e or nozzle and replace as needed The motor stalls when the nozzle is closed The bypass relief valve is stuck Remove and inspect the pressure relief valve Clean or replace if it is damaged The supply...

Страница 11: ...n The fuse or circuit breaker is blown Check the electrical supply There is an electrical problem Check that proper supply voltage is getting to the pump There is a defective switch Replace with a new...

Страница 12: ...Parts 12 3A8569A Parts 9 2 13 18 6 5 4 3 1 12 7 8 10 11 22 14 20 19 21 15 16 17 23 1 2 2 Torque value 20 ft lb 27 1 N m 1 2 Torque value 30 ft lb 40 7 N m...

Страница 13: ...t 1 5 O ring 1 6 Screw 3 8 16 socket head cap 4 7 Ball relief valve 1 8 Pin dowel steel 3 8 x 3 4 1 9 Motor 12 VDC 1 10 Spring relief valve 1 11 Plug 12 npt 1 12 Elbow street 3 4 npt 1 13 Screw cap 5...

Страница 14: ...Kits and Accessories 14 3A8569A Kits and Accessories Part Number Description 133412 Wall mounting kit 260238 Y strainer 260124 Suction tube with inlet check assembly 133376 Dispense kit...

Страница 15: ...Kits and Accessories 3A8569A 15 133372 Pump housing assembly 230 115 V Transfer Pump 133377 Suction filter 133375 Suction kit Part Number Description...

Страница 16: ...Pump Performance Chart 16 3A8569A Pump Performance Chart...

Страница 17: ...Dimensions 3A8569A 17 Dimensions Length A Height B Width C Models Inches mm Inches mm Inches mm 25T819 12 5 317 5 6 5 165 1 6 75 171 4...

Страница 18: ...age 16 3 8 gpm 14 4 L min Dimensions See Dimensions page 17 Hose Size 8 ft 3 4 in ID 2 4 m 19 mm Suction Tube 34 in 864 mm Weight All models 24 0 lb 10 9 kg Motor Details Voltage 12 VDC Current 30 A P...

Страница 19: ...California Proposition 65 3A8569A 19 California Proposition 65 CALIFORNIA RESIDENTS WARNING Cancer and reproductive harm www P65warnings ca gov...

Страница 20: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANT...

Отзывы: