Grace Industries, Inc.
305 Bend Hill Road, Fredonia, PA 16124
Ph. 724-962-9231 Fax 724-962-3611
Front View
with
Accountability
Key In Place
Safety Certifications
Certified Intrinsically Safe to ANSI/UL 913: Class
1, Groups C and D; and Class II, Groups E, F, and
G; Division 1 Hazardous Locations.
CAUTION:
Changes or modifications not expressly
approved by the party responsible for compliance
could void the user’s authority to operate this
equipment.
Warranty Information
Grace Industries, Inc. warrants the Super
PASS
®
3
to be free from defects in workmanship and
materials for a period of one year from the date of
purchase. This warranty is valid only when the re-
turned SuperPASS
®
3 is accompanied by a sales
slip or other proof of purchase that states the date
and location of purchase. Grace Industries, Inc. will
not repair or replace any merchandise under war-
ranty which has been damaged because of acci-
dent, misuse or abuse of the SuperPASS
®
3 while
in possession or control of the consumer. This war-
ranty is void if any attempt to repair or replace parts
was made or attempted by other than qualified
Grace Industries, Inc. personnel. This warranty is
void if any of the sealed compartments are opened
or tampered with. Send all returned merchandise,
prepaid and accompanied by proof of purchase to:
Grace Industries, Inc., Repair Division, 305 Bend
Hill Road, Fredonia, PA 16124. Grace Industries,
Inc. shall not be liable for any direct, incidental or
other consequential loss or damage arising out of
the failure of the device to operate.
The sole and exclusive remedy under all guar-
antees or warranties, expressed or implied, is strictly
limited to repair or replacement as herein provided.
ALL IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO, WARRANTIES OF FITNESS
AND MERCHANTABILITY, ARE HEREBY LIMITED
IN DURATION TO A PERIOD ENDING ONE (1)
YEAR FROM THE DATE OF PURCHASE. The war-
ranty and liability set forth in the prior paragraphs
are in lieu of all other warranties, expressed or im-
plied, in law or in fact, including implied warranties
of merchantability and fitness for a particular pur-
pose. Some states do not allow limitations on how
long an implied warranty lasts, so the above limita-
tions may not apply to you.
This warranty gives you specific legal rights and
you may also have other rights which may vary from
state to state.
The information contained in this booklet is be-
lieved to be accurate and reliable. Grace
Industries, Inc. provides this information as a guide
only.
SuperPASS
®
3 technical assistance is
available by contacting Grace Industries, Inc.
at 724-962-9231.
SuperPASS
®
3 is designed to be automatically acti-
vated into the
Sensing Mode
or turned
ON
when re-
moved from the PASS storage position, whether it is a
transportation or a fixed storage position. When removed
from the storage position, the tether will tighten and the
Accountability Storage Key will automatically pop off
putting SuperPASS
®
3
into the
Sensing Mode
. At this
point, the unit can be
reset
(from the
Alarm Mode
to
Sensing
Mode
) but cannot be turned
OFF
until the
Accountability Storage Key is replaced and both side
buttons pressed simultaneously.
The Accountability Storage Key has an adjustable
tether for ease of use. The tether can be adjusted from
approx. 3' to 6' in length. This allows for easy utilization
whether you are anchoring the tether to a transporta-
tion position (such as to a seat in a vehicle) or a fixed
storage position (such as in the fire station). Account-
ability Storage Keys are available with various length
tethers to facilitate various operational needs.
Internal Datalogger
The internal data logging function records
dates and
times of the last 2,000 events. Recorded PASS events
include: Power On, Pre-Alert and Lack of Motion Alarm,
Manual Alarm, Reset, Power Off and Low Battery Warn-
ings. The datalog information can be downloaded to a
PC using the datalog-transfer software and IR Dongle
available from Grace Industries.
IMPORTANT: To preserve the internal date & time
setting when changing batteries - batteries must
be replaced within 3 minutes of removing the
exhausted set.
The clear Identification Window located on the front of
the key provides the opportunity for specific identity of
the PASS user through the ability to personalize keys
with pictures, names, numbers, dept. ID, bar-codes, etc.
The clear access window easily snaps into place to pro-
tect enclosed information and provide instant access
for quick ID. Information in the Identification Window can
easily be changed by partially popping the ID window
out with a small, flat blade screwdriver through the ac-
cess slot located on the bottom of the ID window.
SUPER PASS
®
3 with
Accountability Storage Key in Place
Pull Away Tether for Auto-On
Activation from Storage Positions
Snap hook attached to Transportation or Fixed
Storage Position.
Pull turnout gear away. Tether tightens and pulls
Accountability Key off the PASS. This will automatically
activate the PASS into the
Sensing Mode
.
PASS
attached to
turnout gear
Snap
Hook
Changing identification information
in the Accountability Storage Key window
Push small screwdriver
through slot on outside
of key. The Plastic I.D.
window will pop out.
Add I.D. information
and Snap window back
in place.
Emergency
Alarm
Button
Auto-On Activation
Inside Battery Cover
Battery Chamber
Bottom View
Accountability
Storage Key
Wire
Attachment
Clip
Side View With
Accountability Key
In Place
Sound Ports
SUPER PASS
®
3
Features and Labeling
© Grace Industries, Inc.
Printed in U.S.A.
P/N SUPERPASS3 0510, UI
USER’S INFORMATION
Only To Be Removed By End User
Front View without Accountability Key
In Place
For training purposes a copy of this information is
available by contacting Grace Industries, Inc.
SuperPASS
®
3 issues may be reported at any time
to Grace Industries, Inc. at 724-962-9231. After
working with the manufacturer to resolve any issues,
they may be reported to SEI at 703-442-5732.
Case Glows when
Accountability
Key Pops Off
Emergency
Alarm
Button
Solutions for Life Safety
Solutions for Life Safety
1.
To
, press both side
buttons simultaneously
when Accountability Key
is Off unit.
To turn
, replace
Accountability Key
and press both side
buttons simultaneously
▲
▲
▲
▲
▲
Identification
Window
▲
Tether Attached To
A Fixed Position
▲
▲
▲
▲
▲
▲
Serial
Number
Label
FIGURE 1
▲
▲
Sealing
Surface
▲
O-ring
I.D. Window
Compliance
Label
▲
Reset
Label
▲
SuperPASS
®
3