77
5. As each of the
3 set screws
aligns with the
timing cut-out, loosen them with the 2 mm
Allen wrench.
Set Screw
(x3)
6
6. The outside part of the hook assembly
(shown in blue) now rotates by hand. Turn
the outside part of the hook assembly so
that the hook is at the top.
Hook
7
7. Carefully rotate the hand wheel to drop
the needle (shown in gray) all the way
to the lowest point. Continue rotating the
hand wheel the same direction. The needle
should begin to raise up.
8
8.
Stop raising the needle once the eye is about
level with the hook (shown in blue). Do not
continue to raise the needle. If the needle
reaches the top of its rotation (over the
hopping foot), start over at step 8.
9
9.
Slip the
timing spacer (shown in blue) into
the hook assembly.
10
9. Turn the hand wheel the opposite direction
to bring the needle back down until it rests
on top of the timing spacer. Do not let the
needle rise to the top before bringing it back
down or you will need to repeat steps 8-11.
11
Timing the Machine (Continued)
Repairs and Diagnostics
Needle