Page 5
MS900-H-R 1117
MS900-H-R
Micro Receiver System Specifi cations
Case:
Rugged fi berglass
Dimensions:
6-1/2” wide by 15” high by 6-1/2” deep
Weight:
10 lb. (with battery backup and light-siren)
Power Input Requirement:
AC
Models:
120 VAC, 60 Hz Single Phase 1Amp
DC
Models:
12 VDC ONLY, 0.5 Amp
Battery (Option):
12 VDC, 2.9 Amp. Hr. (provides emergency, backup power for up to 24 hours)
Frequency Range:
902-928 MHz (frequency hopping spread spectrum)
FCC ID:
J5MXHEM -- Meets FCC Part 15
IC:
5916A-MXHEM -- Complies with Canadian ICES-003
For Use With:
Grace Telemetry Systems using the RadioH platform (SuperCELL SC500, TPASS3,
TPASS5, LTX200, Micro Repeater).
Relay Closure:
4 form-c contact ratings 6A @ 28VDC, 6A @ 125VAC.
MS900-H-R-DC
• Micro-Receiver
System,
12 volt DC
• 1 Default Alarm Output Relay 6A-SPDT - 20 second Hold/Activation time.
• 1 Default Global Evac Relay 6A-SPDT - 20 second Hold/Activation time.
• Indoor coverage of 120k sq. feet and 1/2 mile outdoor clear line of site - Indoor Performance is
subject to the effects of building construction and RF noise.
MS900-H-R-AC
• Micro-Receiver
System,
120 volt AC
• 1 Default Alarm Output Relay 6A-SPDT - 20 second Hold/Activation time.
• 1 Default Global Evac Relay 6A-SPDT - 20 second Hold/Activation time.
• Indoor coverage of 120k sq. feet and 1/2 mile outdoor clear line of site - Indoor Performance is
subject to the effects of building construction and RF noise.
MS900-H-R-AC-B
• Micro-Receiver
System,
120 volt AC, includes battery backup
• 1 Default Alarm Output Relay 6A-SPDT - 20 second Hold/Activation time.
• 1 Default Global Evac Relay 6A-SPDT - 20 second Hold/Activation time.
• Indoor coverage of 120k sq. feet and 1/2 mile outdoor clear line of site - Indoor Performance is
subject to the effects of building construction and RF noise.
MS900-H-R-AC-B-LS
• Micro-Receiver
System,
120 volt AC, includes battery backup with light/siren
• 1 Default Alarm Output Relay 6A-SPDT - 20 second Hold/Activation time.
• 1 Default Global Evac Relay 6A-SPDT - 20 second Hold/Activation time.
• Indoor coverage of 120k sq. feet and 1/2 mile outdoor clear line of site - Indoor Performance is