GQ Electronics GMC-500 Скачать руководство пользователя страница 7

 

 

 

Hardware setup 

 
There are four buttons on the front of the unit: S1, S2, S3 and S4 (from left to right) 

 

1.  Power  up  the  unit.    Pressing  the  S4  (power)  key  for  3  seconds  will  turn  on  the  unit. 

Check  the  battery  level.    Charge  the  battery  fully  when  first  time  use.  
It may take a few hours to get the battery fully charged. Check the battery icon on the display, 
a fully charged battery icon will be filled with solid color, without flashing. 

2.  Set date/time.  Press the S4 key to enter the menu and set the date and time. This is very 

important  for  time  stamping  the  recorded  data.  Do  not  skip  this  step.  Most  of  the  data  are 
related to the date and time. 

3.  Set  the  backlight  timeout  in  second,  in  order  to  minimize  the  power  consumption.  

Set the power savings mode.  If the power savings mode is ON, then the LCD display will be 
turned off after 30 second if no key is being pressed during this period. 

4.  Now  the  unit  is  ready  to  use.    You  should  see  the  background  CPM  rate  in  absence  of  a 

radioactive source. 

 
Note:  There is a transparent protective sheet covering the units surface. Users need to remove it to 
get better view of the LCD display. 
 
 

Software set up 

 

Before  connecting  the  GMC-500/GMC-500+  Geiger  Counter  to  a  computer,  download  the 
application 

software 

and 

install 

the 

USB 

driver. 

 

Download 

these 

from: 

http://www.gqelectronicsllc.com. 
 

1.  The  unit  needs  an  USB  driver  in  order  to  communicate  with  the  application  software. 

Running 

GQGMCGeigerCounterUSBDriverV4.exe

 will install the USB driver.   

2.  GMCDataViewer.exe is for viewing the data on a computer. 
3.  SoftGeigerCounterGMC500.exe is a soft copy of GMC-500 demo software. 

 
 
 
 
For technical questions and support, please use the forum at the following link: 
 

http://www.GQElectronicsLLC.com/forum

 

 
 
For the latest software, please visit our software download page: 
 

http://www.gqelectronicsllc.com/comersus/store/download.asp

 

 

Содержание GMC-500

Страница 1: ...GQ GMC 500 GMC 500 Geiger Counter User Guide GQ Electronics LLC Revision 1 2 Sep 2017...

Страница 2: ...2 Document Revision History Re 1 20 Sep 2017 Re 1 01 Apr 2017 Re 1 00 Feb 2017...

Страница 3: ...ng 16 Data Saving Setting 16 Threshold Data Saving Setting 17 Add Note or Add Location for data saving 17 Note Location Input 18 Erase Saved History Data 18 Display Option 18 Swivel Display Option 18...

Страница 4: ...version 28 Unit serial number 28 GQ GMC Data Viewer Software 29 Online Geiger Counter World Map 32 www GMCmap com 32 Software 32 Auto Submit Data Protocol 32 Applications 33 Stationary Application 33...

Страница 5: ...th the a standard USB port USB charger or with a computer USB port Using the external power continuous data monitoring is possible Using either power adapter you will not have to worry about the batte...

Страница 6: ...ion to location To get accurate reading user may need to get an average value over a longer time period The GM 500 built in intelligent algorithm always select one of the most adequate sensors to meas...

Страница 7: ...fter 30 second if no key is being pressed during this period 4 Now the unit is ready to use You should see the background CPM rate in absence of a radioactive source Note There is a transparent protec...

Страница 8: ...m the device manger you should see which COM port is assigned to the unit See the example below Windows assigned COM3 to the GMC 500 unit in this example For the data viewer or the data logger softwar...

Страница 9: ...the highlight menu item upwards 4 In the menu mode while a popup message box is opened the S2 key changes the value by cycling through the predefined values S3 key 1 In text mode pressing the S3 key...

Страница 10: ...l be stored when the Popup Window has timed out after 3 seconds if no key has been pressed Graphic User Interface GUI Graphic Icons Graphic ZOOM factors 0 5 1 0 2 0 AUTO Battery Status Data saving ena...

Страница 11: ...11 Average CPM of a specific time frame Maximum CPM since power on Current radiation level is normal Current radiation level is medium Current radiation level is high...

Страница 12: ...isplay preferences Vertical Display and Horizontal Display With the Horizontal Display the user can select one information screen from Text Graphic Large Font or Menu The Vertical Display Mode display...

Страница 13: ...ode and Timed Count Graphic Mode Current radiation level reading in CPM format Counts Per Minute CPS Count Per Second in last 60 seconds Text Mode Current date and time Press S3 for toggling between d...

Страница 14: ...ys for both modes S1 Text Graphic Display Mode Selection S2 Sv h mR h Total Count Elapsed Time selection S3 Date or Time on title selection S4 Menu Large Font Mode Current date and time Change it in T...

Страница 15: ...Back S2 Up S3 Down S4 Select Enter User Option Navigation keys S1 Back S2 Up S3 Down S4 Select Enter Alarm Set Currently the CPM alarm mode is selected The audio alarm will be triggered once the radia...

Страница 16: ...d the key down S4 Select setting mode between Year Month Date Hour Minute and Second Each key press will change the mode to be set NOTE Setting of Date and Time is important all history data use Date...

Страница 17: ...will be over written Carefully select the data saving interval to save memory space With Threshold saving mode data only will be logged if it exceed the threshold value Threshold Data Saving Setting...

Страница 18: ...and S3 to select Yes or No on the screen to confirm the request After about 3 seconds with Yes confirmation the unit will start to erase entire saved history data It may take a few seconds to complet...

Страница 19: ...SK TKIP AES and Open security modes Select WiFi On Off item will turn the WiFi connection On Off Make sure the WiFi SSID and Password have been set Note All WiFi settings available from GQ GMC Data Vi...

Страница 20: ...to another http server URL for Website server The default web server data receiving URL is log2 asp User is able to change the URL to user specific URL However the URL data parameters in a fixed forma...

Страница 21: ...ging Period The default data logging period is 2 minutes This will let unit to log the data to website server every two minute User is able to change the period from 1 to any minutes WiFi Data Logging...

Страница 22: ...user can enter up to three calibration points from large to high count rates Procedure 1 Place the testing radiation source 30mm away to the center of unit Geiger Tube side In Text or Graphic mode wai...

Страница 23: ...cedure Select Factory Reset menu item and change the popup Windows message to Yes Wait for popup message window s timeout to confirm the reset request Any other key press will cancel the reset request...

Страница 24: ...y power The audio signal will not be turned off if it has been set to ON The LCD back light will be off during the power saving mode Pressing any key will active the LCD backlight again The unit movem...

Страница 25: ...gyroscope data It displays current unit X Y Z axis data and detected motion event Such as single tap OR double tap Communication Baud Rate This Geiger counter serial communication baud rate is selecta...

Страница 26: ...edule the Timed Count will be started immediately once the timed count period is set The Timed Count can be set from the menu Set a schedule This example shows the schedule is set to 2 minute Navigati...

Страница 27: ...starts immediately after the duration set If the Schedule is set then the Timed Count will be started after a scheduled time period passed This is useful if a testing target is not ready immediately O...

Страница 28: ...28 About This menu item is used to gather information about the instruments model number firmware revision and serial number Model information Firmware version Unit serial number...

Страница 29: ...y data from GMC 500 Real time monitoring with graphic when it connected with GMC 500 Save the history data in bin OR csv MS Excel format Synchronize the data and time to GMC 500 with computer s data a...

Страница 30: ...30 WiFi Setup Utility With Data Viewer software Settings menu users are able to quick and easily setup the device WiFi connection and data logging...

Страница 31: ...PEAKER1 ALARM0 ALARM1 GETVOLT GETGYRO GETCFG GETCPS GETTEMP HEARTBEAT0 HEARTBEAT1 GETDATETIME CFGUPDATE POWEROFF POWERON SETDATETIME FACTORYRESET For detailed communication protocol commands please se...

Страница 32: ...any software automatically submitted data The following tested software are free for automatic submit data feature 1 GQ Geiger Counter Data Logger PRO works on all Geiger Counter 2 GQ Geiger Counter D...

Страница 33: ...0 075 The result will be returned immediately The following are the returned result examples 1 OK 2 Error User is not found 3 Error Geiger Counter is not found 4 Warning The Geiger Counter location c...

Страница 34: ...e Power Saving mode to extend the battery operating time Turn off the speaker if it is not necessary If a fully charged battery run out in less than 5 operating hours then the battery needs to be repl...

Отзывы: