Observe precautions against electrical shock when servicing the 

pump. 

Always

 disconnect power before repairing or servicing. 

Never

  apply  electrical  power  to  the  system  when  any  of  the 

coverplates are removed.
If using solvent to clean pump components or tank, observe the sol-

vent manufacturer’s recommendations for safe use and disposal.

This pump is designed to self-prime with dry gears.
Make sure all threaded fuel connections are wrapped with three 

to four turns of Teflon

®

 tape or a pipe thread sealant approved 

for use with petroleum fuels.
Clean and bond the suction pipe top and bottom as necessary. 

Thread the suction pipe into the inlet fitting and tighten snugly. Trim 

the suction pipe as necessary to leave approximately 1/2 in. (1.2 

cm) clearance from the bottom of the tank. Clean the tank interior 

of all dirt and debris. Insert the suction pipe into the tank opening. 

Tighten the pump onto the tank adapter. Do not cross thread.
Make sure the tank is vented. A vent cap rated at 3 psi or less is 
recommended.

Install Electrical Connections

A grounding connection is provided. It is identified as a green 

colored binding head screw in the electrical cavity. Connect these 

pumps only to a 12-volt DC power source. Do not connect to a 

24-volt DC, 115-volt AC or 230-volt AC power source.
For installation in unclassified areas, the supplied power cord, 

fuse and strain relief grip may be used.
NOTE:  These components have not been evaluated as part of 

the UL Listed Equipment and are not intended for use in a 

Hazardous (Classified) Location.

To  install  the  power  cord,  remove  the  electrical  coverplate.  If 

necessary, trim the power cord to the desired length. Strip 3 to 

4 inches (7.5 to 10 cm) of outer insulation from the power cord 

end. Then strip 1/2 in. (1.3 cm) of insulation from the power cord 

wires. Slide the strain relief grip onto the power cord so that the 

threaded end of the strain relief grip faces the stripped power cord 

wires. Insert the power cord through the 1/2 inch NPT connection 

on the back of the pump. Using wire nuts, connect black wire to 

black and red wire to red in the pump’s electrical cavity. Position 

the wires inside the electrical cavity and tighten the strain relief 

grip securely. Make sure surfaces are clean. Install the coverplate 

and tighten securely.

OPERATION

Install Hose and Nozzle

After sealing threads, tighten the hose into the pump outlet 

and the nozzle on the hose. The nozzle can be placed in the 

nozzle holder only when the pump is off.

AlwAys  follow  sAfETy  prECAuTIoNs  wHEN  opErAT-

INg THIs EquIpmENT. rEvIEw THE sAfETy INsTruCTIoNs.

 

Before each use, repair leaks around seals or connections. Make 

sure hoses are in good condition and connections are tight. Make 

sure the work area is dry. 

mAkE surE THE pump Is propErly 

grouNDED.

 Repair any corroded or damaged wiring before use. 

Ensure the tank contains enough fuel. Make sure the fuel is not 

contaminated with debris. Tighten loose tank lids regularly.

To Dispense fuel

Turn on the pump by removing the nozzle from the holder and push-

ing up the switch lever. Insert the nozzle into the receiving tank and 

squeeze the handle to start fuel flow. When done, release the nozzle 

handle, turn the pump off, and return the nozzle to its holder.
This pump is designed to be self-priming. If fuel is not delivered 

within 15 to 20 seconds, turn the pump off and refer to priming 

information in the Troubleshooting Section. 
An automatic bypass valve prevents pressure build up when the 

pump is on with the nozzle closed. To avoid pump damage, do 

not run the pump more than 5 minutes with the nozzle closed.
After running the pump for a maximum of 15 minutes, allow it to 

cool for 30 minutes.

Auxiliary Temperature-limiting Device

The  motor  is  provided  with  an  internal  auxiliary  temperature-

limiting device. Excessive motor heat can trip the device. It resets 

automatically after the motor has cooled.

This pump is designed for minimum maintenance. Motor bear-

ings are sealed and require no lubrication. Inspect the pump and 

components regularly for fuel leaks and make sure the hose and 

power cord are in good condition. Keep the pump exterior clean 

to help identify leaks.
Do not use this pump for water, chemicals or herbicides. Dispens-

ing any fluid other than that listed in this manual will damage the 

pump.  Use  of  the  pump  with  unauthorized  fluids  will  void  the 

warranty.

If pump is to be installed in a Hazardous (Classified) location, 

it must be installed by a licensed electrician and conform to 

National fire protection Association (NfpA) codes 30 and 70. 

you as the owner, are responsible for seeing that the installa-

tion and operation of your pump complies with NfpA codes 

as well as any applicable state and local codes. rigid conduit 

must be used to install wiring. Note that the lead wires are 

factory-sealed isolating the motor from the junction box.
failure to follow these wiring instructions may result in death 

or serious injury from shock, fire or explosion.

INSTALLATION

Carefully route the power cord to the battery, protecting the 

power cord from hot surfaces, sharp edges or anything that 

could damage the power cord, resulting in a short circuit.

MAINTENANCE

A 20-amp fuse is provided to protect the motor and power 

cord. Install fuse in the red wire of the power cord adjacent 

to the battery. Connect the red wire of the fuse to the positive 

(ungrounded) side of the battery. Connect black wire to the 

negative (grounded) side of the battery.