EZ-8-Methanol Pump

GENERAL  INFORMATION

These instructions will help you operate and maintain your pump. 

This owner’s manual covers the EZ-8-Methanol, 12-Volt electric 

gear pump.

Do not leave the system running without fluids. “Dry running” can 

damage the pump. If the system fails to deliver fuel after 15 to 

20 seconds, turn the system off and refer to the Troubleshooting 

Section.
Do not pump the tank completely dry, as contaminants from the 

bottom of the tank may enter the pump.

Observe all safety precautions concerning safe handling of pe-

troleum fuels.
To ensure safe operation, all fuel transfer systems must be properly 

grounded. Proper grounding means a continuous metal-to-metal 

contact from one component to the next,  including  tank,  bung,  

pump, meter, filter, hose, and nozzle. Care should be taken to 

ensure proper grounding during initial installation and after any 

service or repair procedures. For your safety, please take a mo-

ment to review the warnings below.
To  prevent  physical  injury,  observe  precautions  against  fire  or 

explosion when dispensing fuel. Do not operate the system in 

the presence of any source of ignition including running or hot 

engines, lighted cigarettes, or gas or electric heaters. 
Observe precautions against electrical shock when operating the 

system. Serious or fatal shock can result from operating electrical 

equipment in damp or wet locations.
Inspect external pump wiring regularly to make sure it is correctly 

attached to the battery. To avoid electrical shock, use extra care 

when connecting the pump to power.
Avoid prolonged skin contact with fuels. Use protective goggles, 

gloves, and aprons in case of splashing or spills. Change saturated 

clothing and wash skin promptly with soap and water.

SAVE THIS OWNER’S MANUAL

Notice

: This pump is not intended 

to be used with an automatic nozzle.

An automatic bypass valve prevents pressure build up when the 

pump is on with the nozzle closed. To avoid motor damage, do 

not run the pump more than 5 minutes with the nozzle closed.

The rated duty cycle of this pump is 15 minutes ON and 30 minutes 

OFF. Allow the pump to cool for 30 minutes.
This  pump  is  specifically  designed  for  use  with  methanol  and 

ethanol. The pump is also compatible with gasoline, diesel fuel 

(up to 20% biodiesel blends such as B20) and kerosene. 

Do not

 

use this pump for dispensing any fluids other than those for which 

it was designed. To do so may damage pump components and 

will void the warranty.
This pump is designed to operate on a typical 12-volt DC auto-

motive electrical system. The pump is designed to operate with 

12-volts DC at the motor leads and the ratings are determined at 

this voltage. Performance may vary due to length of power cord, 

battery condition or output from vehicle charging system that will 

affect system voltage. 

SAFETY  INSTRUCTIONS