GPI 01N31GM Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

01N31GM, 01N31LM 

and

 

01N12LM Electronic Water Meters 

 

 

 

 

 

 

 

 

 

 

 

Batteries Included 

 

 

IMPORTANT NOTICE 

Use this meter for water only. Do not use to me-

ter fuel or chemicals. 

This meter is not legal for trade applications. 
The meter is very sensitive to electrical “noise” 

and may not operate correctly if located near some 

electrical equipment. 

CALIBRATION 

This meter has a permanent factory calibration 

for measuring water. If installed and used correctly, 

inaccuracies of no greater than ±5% will be ob-

tained. 

INSTALLATION 

This meter may be installed in-line either horizon- 

tally or vertically or at the end of the hose adjacent to 

the nozzle, if present. Installation to metal connec-

tions is not recommended. Install as follows: 
1.  If necessary, remove nozzle from hose. 

2.  Apply pipe sealant to all threaded connec-

tions. 

3.  Attach meter to hose with arrow on outlet port 

pointed in the direction of flow. 

4.  If necessary, attach nozzle to meter. 
5.  Hand tighten the meter at the housing ends. Do 

not use a wrench or similar tools to tighten the 

meter housing. The plastic housing could be 

damaged. 

OPERATION

 

Batch and Accumulative Totals 

The meter maintains two totals. The batch total 

may be reset to measure flow during a single use. 

The accumulative total provides continuous meas-

urement and may not be manually reset. The batch 

total is labeled as TTL1. The accumulative total is 

labeled TTL2. 

When the accumulative total reaches a maxi-

mum reading of 9999, it will automatically reset to 

zero. 

Press the DISPLAY button briefly to switch be-

tween the batch and accumulative totals. 

Activate the Meter 

Turn the meter ON by starting water flow or 

briefly pressing the DISPLAY button. The meter will 

display the batch or accumulative total from last 

use. 

Press DISPLAY briefly to display the batch total. 

Hold the DISPLAY button down for three seconds 

to reset the batch total to zero. 

The meter is programmed to turn off automati-

cally if not used for about one minute. 

MAINTENANCE

 

Proper handling and care will extend the life and 

service of the meter. 

Turbine Rotor 

The 01N Series meter is virtually maintenance- 

free. However, it is important that the rotor move 

freely. Keep the meter clean and free of contami-

nants. 

If the rotor does not turn freely, apply a pene-

trating lubricant on the rotor, shaft, and bearings. 

Remove any debris or deposits from the rotor using 

a soft brush or small probe. Be careful not to dam-

age the turbine rotor or supports. 

CAUTION: Blowing compressed air through the 

turbine assembly could damage the rotor. 

 