INTRODUCTION
GoWISE Power Pure Sine Wave Inverters are protected by a variety of features
including:
Reverse Polarity Protection
The fuses will burn out when the positive and negative cables are reverse
connected to protect the inverter.
Low Battery Shutdown
When the inverter is in low voltage, an alarm will go off first and if the voltage
continues to reduce, the LCD will turn red and the inverter will shut down. If the
voltage rises to 12V +/- 0.5V, the inverter will automatically restart and the LCD
will turn from blue to green.
Over Temperature Protection
The inverter will automatically protects itself when it reaches a high
temperature. An alarm will go off first then the LCD will be red. The inverter will
shut down and auto-restart.
Overload Protection
The inverter will automatcially protect itself when the load is too high. An alarm
will go off first then the LCD will be red. The inverter will automatically shut
down. The inverter will need to be restarted manually.
Over Voltage Protection
The inverter will automatically protect itself when it is in high voltage. The LCD
will be red and the inverter will automatically shut down. When the voltage drop
to 15.5V +/- 0.5V, the inverter will auto restart.
Output Short Circuit Protection
The inverter will automatically self protect the unit by shutting down in the event
of a short circuit. It will auto restart after shutting down when the short circuit is
removed.
5
Содержание PS1007
Страница 21: ...21 NOTES...