background image

8

1. After the positioning sensor has been set, the words “SND ON” will appear on the screen. This

means that the voice function is on, press the power button to keep the voice function on. If
you wish to turn the voice function off, press “MEM” and the words “SND OFF” will appear on
the screen. Press the

to save the setting.

NOTE: If you turn the voice function on, the monitor will beep instead of speaking to you.
If you turned off the voice function and wish to turn it on, press and hold “SET” and it will take you
through the whole set up. Keep pressing “SET” until you get to the Voice function setting then press
“MEM” to turn it back on. Below the “SND ON” on the display is the volume level. After you turn the
voice function on, press “MEM” continually to turn up the volume, it can be set between levels 1 and 7,
then press the power button to save the setting.

SWITCHING USERS

This blood pressure monitor is for two users with a 90 memory recall for each.

1. After you have set up this blood pressure monitor, the monitor will be off. Press the “SET”

button and a user mark will appear. Press

to confirm the user and the

MEASUREMENT

g the wrist cu

1. Remove all accessories (e.g. watch, bracelet) from your

wrist. If your physician has

diagnosed you with poor

n in your

arm, use your right wrist.

2. Roll or push up your sleeve to expose the skin.

SET

MEM

SET

MEM

Sound Symbol

Volume Level

Volume Level 7

Volume Level 0

Volume Level 1

Voice ON/OFF

SET

MEM

MEM

MEM

"       "

"       "

monitor will turn off.

Содержание GW22059

Страница 1: ...W22059 GoWISE USAR www gowiseusa com info gowiseusa com 1 855 233 9199 Thank you for purchasing this GoWISE USA Blood Pressure Monitor To assure correct use of this monitor read these instructions car...

Страница 2: ...F RECORDS Recall records 10 Delete records 11 INFORMATION FOR USER Tips for operation 12 Maintenance 13 ABOUT BLOOD PRESSURE What are systolic pressure and diastolic pressure 13 What is the standard b...

Страница 3: ...xtremi es other than the wrist or for fluctua s other than obtaining a blood pressure measurement Do not confuse self monitoring with self diagnosis thisunit allows you to monitor your blood pressure...

Страница 4: ...lood pressure High pressure result Diastolic blood pressure Low pressure result BPM Motion will result in inaccurate measurements Memory If M shows the displayed measurement values is from the memory...

Страница 5: ...acement of batteries 1 Slide off the battery cover 2 Install the batteries by matching the correct polarity as shown 3 Replace the cover Body Cuff Voice Display Battery Compartment Wrist Cuff Setting...

Страница 6: ...calculates standard The device displays a warning signal with the reading to indicate the detection of irregular heartbeat when the di erence of th e intervals is over 25 HOW TO SET UP YOUR BLOOD PRE...

Страница 7: ...ure in blood pressure monitors that tells the user whether the position of the blood pressure monitor is too high or too low The positioning sensor symbol is the shape of a heart with two arrows going...

Страница 8: ...elow the SND ON on the display is the volume level After you turn the voice function on press MEM continually to turn up the volume it can be set between levels 1 and 7 then press the power button to...

Страница 9: ...y measurements at approximately the same time and same or as directed by a physician Start a measurement 1 Choose a user then press 2 Press the to turn on the monitor If the cuff is not in the proper...

Страница 10: ...will show you the average value of all AM or morning readings 3 Press MEM again and it will show you the average value of all PM or afternoon evenings readings 4 Press MEM again to display each readin...

Страница 11: ...delete all results by following these steps 1 When the unit is o switch to the user you want to delete records for then press Press MEM briefly to turn on the appropriate screen Then press and hold ME...

Страница 12: ...er these Wait at least 1 hour r dinner or drinking Do not measure immediately r tea co ee smoking Wait at least 20 minutes er taking a bath Do not measure in very cold environment Do not measure when...

Страница 13: ...r Avoid dusty environment and unstable temperature Avoid washing the cu ABOUT BLOOD PRESSURE What are systolic pressure and diastolic pressure Systolic blood discharging Diastolic blood entering arter...

Страница 14: ...160 179 180 DIA 80 80 84 85 89 90 99 100 109 110 CAUTION The standard blood pressure classification provided above is for GENERAL INFORMATION ONLY YOU MUST CONSULT YOUR PHYSICIAN or a licensed healthc...

Страница 15: ...eadings because the settings and properties are not all the same In addition blood pressure changes throughout the day due to circumstances such as stress or weather When taking your blood pressure at...

Страница 16: ...ies power are too low The course of inflating appears error When measurement fails Correction Cause Symbol Replace both of the worn batteries with two new ones Blood pressure varies constantly Many fa...

Страница 17: ...kPa 3 Digits Display Memory IHB Heartbeat Low Battery etc 3 mmHg 0 4kPa 5 of reading Pulse Internal power supply appliance type B LCD Indication Symbol Memory 180 2 90 Sets Measurement Values Automati...

Страница 18: ...l not be liable for loss of use or any other incidental consequential or indirect costs expenses or damages There are no express warranties except as listed above This warranty gives you specific lega...

Отзывы: