122
304
198A
Figure 43: Impeller removal
3.
Pull the impeller (101) from the shaft (122).
Use a spanning-type puller if required.
4.
Remove the impeller key (178).
Save the key for reassembly unless it is damaged.
6.4.7 Remove venturi insert (venturi pumps only)
1.
Loosen insert hex nuts (362B).
2.
Tighten the jackscrews (362C) evenly in order to remove the venturi insert (100W).
100
362A
351O
100W
362C
362B
Figure 44: Venturi insert removal
3.
Clean all gasket surfaces. Clean surfaces prevent the insert gasket (351O) from partially adhering
to the case (100) and insert (100W) due to binders and adhesives in the gasket material.
6.4 Disassembly
72
Model 3700i API610 / Type OH2 Installation, Operation, and Maintenance Manual