http://www.gouldspumps.com/en-us/tools
or your local ITT Goulds Pumps Sales Rep.
Alarm mode
The condition monitor enters alarm mode when either vibration or temperature limits are exceeded over
two consecutive readings within a user defined period. Alarm mode is indicated with red flashing LED.
Table 4: Temperature and vibration limits
Variable
Limit
Temperature 100°C | 195°F Surface Temperature
Vibration
100% increase over the baseline level
Battery life
The i-ALERT®3 Condition Monitor battery is replaceable.
The battery life is not covered as part of the standard pump warranty.
This table shows the average condition monitor battery life under normal and alarm-mode operating con-
ditions.
Condition monitor operational state
Battery life
Normal operating and environmental conditions
Three to five years
Alarm mode
One year
3.3 Nameplate information
Important information for ordering
Every pump has a nameplate that provides information about the pump. The nameplate is located on the
pump casing.
When you order spare parts, identify this pump information:
•
Model
•
Size
•
Serial number
•
Item numbers of the required parts
Item numbers can be found in the spare parts list.
Refer to the nameplate on the pump casing for most of the information. See Parts List for item numbers.
Nameplate types
Nameplate
Description
Pump casing
Provides information about the hydraulic characteristics of the pump.
Pump
The formula for the pump size is: Discharge x Suction - Nominal Maximum Impeller Diameter in
inches.
(Example: 2x3-8)
ATEX
If applicable, your pump unit might have an ATEX nameplate affixed to the pump, the base-
plate, or the discharge head. The nameplate provides information about the ATEX specifica-
tions of this pump.
IECEx
If applicable, your pump unit might have the following IECEx nameplate affixed to the pump
and/or baseplate. The nameplate provides information about the IECEx specifications of this
pump.
3.3 Nameplate information
20
Model 3700i API610 / Type OH2 Installation, Operation, and Maintenance Manual