Goudsmit SFH Hygienic Series Скачать руководство пользователя страница 9

 

 

 

Construction and functioning of manual filter 

 

 

 

 

 

 

Function 

 

The function of the device is to capture ferromagnetic particles in the product stream. 
The product flows through the pipe and around the central magnets, these capture ferromagnetic 

particles. 
When disposing of the particles, the extractor unit must first be removed from the housing. Only then will 

the notched handles allow the magnets to be removed from the extractor. 
 

When cleaning the manual filters of ferromagnetic particles 

 

 

Stop product flow. 

 

Loosen clamps and remove extractor with magnets unit, from the housing. 

 

Loosen the notched handles and remove the magnet unit from the extractor. 

 

Place the magnet unit away from the extractor.  

 

Clean the ferromagnetic particles from the extractor with a clean soft cloth or brush. 

 

Dispose of ferromagnetic debris. 

 

Replace magnet unit in extractor and refasten. 

 

Replace extractor and magnet unit in housing and refasten. 

 

Resume product flow. 

 

House

 

Product pipe

 

Clamp

 

Seal

 

Notched 

handle 

 

Notched 

handle

 

Manual 

extractor

 

Clamp

 

Extractor 

rod

 

House

 

Magnets 

 

Flange

 

Handle

 

Содержание SFH Hygienic Series

Страница 1: ...magnetic filter Hygienic series SFH GOUDSMIT Magnetic Systems B V P O Box 18 5580 AA Waalre Petunialaan 19 5582 HA Waalre The Netherlands Tel 31 0 40 2213283 Internet www goudsmitmagnets com E mail in...

Страница 2: ...on start up and servicing 10 The information we supply may only be used for service or operation of the product It may not be disclosed to any third parties without our prior written permission Our pr...

Страница 3: ...3 SFH filter manual version 07 2016...

Страница 4: ...magnetic field of the device Danger to electronic and mechanical devices Magnetic information carriers or electronic and mechanical devices etc may be destroyed if they enter the magnetic field Warnin...

Страница 5: ...5 Identification plate If you need to correspond about your device make a note of the numbers on the identification plate In some cases the plate may be replaced by etched identification numbers...

Страница 6: ...move magnet in the out position Ensure enough time is given for the disposal of ferromagnetic particles the drain pipe may also be used for sampling Pneumatically move magnet in the in position Stop f...

Страница 7: ...ing valve Normal product flow is resumed When cleaning the filter of ferromagnetic particles without any valves Dispose of ferromagnetic particles through another outlet in the installation Please not...

Страница 8: ...e and around the central magnet and the magnet captures ferromagnetic particles When disposing of the particles the central magnet inside the pneumatic bar moves down allowing the particles to be flus...

Страница 9: ...cleaning the manual filters of ferromagnetic particles Stop product flow Loosen clamps and remove extractor with magnets unit from the housing Loosen the notched handles and remove the magnet unit fro...

Страница 10: ...e has no damages or malfunctions and all connections whether mechanical or pneumatic are made properly The filter correctly is installed and at the proper work height Never install with both the two c...

Отзывы: