9
Construction and functioning of manual filter
Function
The function of the device is to capture ferromagnetic particles in the product stream.
The product flows through the pipe and around the central magnets, these capture ferromagnetic
particles.
When disposing of the particles, the extractor unit must first be removed from the housing. Only then will
the notched handles allow the magnets to be removed from the extractor.
When cleaning the manual filters of ferromagnetic particles
•
Stop product flow.
•
Loosen clamps and remove extractor with magnets unit, from the housing.
•
Loosen the notched handles and remove the magnet unit from the extractor.
•
Place the magnet unit away from the extractor.
•
Clean the ferromagnetic particles from the extractor with a clean soft cloth or brush.
•
Dispose of ferromagnetic debris.
•
Replace magnet unit in extractor and refasten.
•
Replace extractor and magnet unit in housing and refasten.
•
Resume product flow.
House
Product pipe
Clamp
Seal
Notched
handle
Notched
handle
Manual
extractor
Clamp
Extractor
rod
House
Magnets
Flange
Handle
Содержание SFH Hygienic Series
Страница 3: ...3 SFH filter manual version 07 2016...