Goudsmit Neoflux SFD Series Скачать руководство пользователя страница 3

Introduction 

 

User manual Neoflux® quick-cleaning magnetic filter 

Introduction 

 

 

 

 

Read this manual and make sure that you fully 

understand its contents before commissioning and 

operating the machine. 

 

If you have any queries or require further explanation 

regarding any subject related to the machine, please 

do not hesitate to contact 

GOUDSMIT Magnetic 

Systems B.V.

 

 

All technical information contained in this manual, 

together with any relevant drawings and technical 

descriptions we supply, remain our property. It may 

not be duplicated or disclosed without our prior written 

permission. 

 

The user manual can be ordered together with the 

device description and/or the article number as well as 

the order number (ORxxxxxx). 

 

 

  This manual and the declaration by the manufacturer are part of the machine. 

  They must remain with the machine, even if it is sold. 

  The manual must be made available to all operators, service technicians, and 

others who work with the machine throughout its life cycle. 

 

 

 

Содержание Neoflux SFD Series

Страница 1: ...r pressure The descriptions and pictures in this manual used for explanation may differ from your execution We have enclosed the as built drawing of the delivered article GOUDSMIT Magnetic Systems B V...

Страница 2: ...n of the user manual 2 0 01 2004 Complete renewed version of the manual 2 1 11 2006 1 Revisions page added 2 Atex remarks added to pages 7 8 9 12 16 and 18 2 2 08 2009 Specification sheet and declarat...

Страница 3: ...contained in this manual together with any relevant drawings and technical descriptions we supply remain our property It may not be duplicated or disclosed without our prior written permission The use...

Страница 4: ...plosive zone measures 8 Safety 9 General 9 Danger of dust explosion 9 Danger of magnetic field 10 Device description 11 Intended use user indications 11 Deliverable specials 12 Working principle 13 Co...

Страница 5: ...tion and or model of our products at any time whatsoever without any obligation to modify any previously supplied products accordingly Ferromagnetism The working principle of the device rests on Ferro...

Страница 6: ...Lubrication products other than those prescribed are used The equipment is used injudiciously incorrectly negligently or not in accordance with its intent and or purpose see chapter Intended use user...

Страница 7: ...identification plate as pictured below Information on this plate is of great importance in case of service That is why we advise to maintain this plate on the device at all times Ensure that it is alw...

Страница 8: ...s been ordered for use in a potentially explosive area make sure that no higher surface temperature arises then permitted by ATEX The ATEX marking on the Goudsmit identification plate only applies to...

Страница 9: ...arning pictograms If the device remains easily accessible to persons then extra safety precautions e g fencing must be installed When safeguards are not possible make sure clear instructions are given...

Страница 10: ...our keys Make use of non magnetic tools and workbenches fitted with a wooden worktop and preferably a non Fe frame for instance stainless steel Always be aware that Ferromagnetic parts will be attract...

Страница 11: ...can be achieved by even more powerful Neoflux magnets Temperatures Suited for product temperatures up to C or higher or up to 200 C with special high temp magnet material dependant on magnet type See...

Страница 12: ...used satisfactory in your specific food flow It s standard execution already is delivered in gap free SS AISI316 or AISI316 L but can be made in combination with other for instance prescribed or deliv...

Страница 13: ...eared to the removal of Fe particles from products that tend to coagulate such as chocolate The industrial filters used for this purpose are fitted with a double wall to allow a continuous flow of hot...

Страница 14: ...clamp the extractor plate to the housing The magnet bar unit has magnet bars with enclosing SS tubes that are welded to an end plate with a hand grip at the other side The magnet bar unit can be pulle...

Страница 15: ...mi automatic magnetic filter the second stage will automatically take place pneumatically 5 Clean the magnet bars manually with soft cloth and safety gloves Clean extra with a soft cloth and or a suit...

Страница 16: ...folding lifting devices ladders and other help materials so the device can be lifted transported and installed without safety risks Magnet bar protection The magnetic filter has fragile extractor tube...

Страница 17: ...tly All protective covers if applicable have been fitted correctly That all objects larger than 10mm are blocked from entering the product channel The device is thoroughly cleaned internally and exter...

Страница 18: ...ide bars with for instance tungsten carbide Please contact GOUDSMIT magnetic systems for advice During maintenance and or cleaning one has to be careful with the magnet bars to prevent them from getti...

Страница 19: ...are ferromagnetic using a permanent magnet Ferromagnetic parts close to the magnet reduce the magnetic field strength Check if there are ferromagnetic parts close to the bar If so try to replace the f...

Страница 20: ...by quoting the type number stated on the identification plate or on one of the drawing s added to this user manual in the added data sheet The spare parts are mostly wear parts such as extractor tube...

Страница 21: ...to conserve fragile and or sensitive parts Dismantling scrapping On scrapping and or disposal of the device s parts separately take into account the different nature and dangers of the components magn...

Отзывы: