Device Description HG G-7335xZA | English, Revision 05 | Date: 19.02.2020
37
CAN Interface (HG G-73350) – Chapter 8
8.5.4.3 COB-ID SYNC message
8.5.4.4 Device Name
8.5.4.5 Hardware Version
8.5.4.6 Software Version
8.5.4.7 Save Parameter
By writing the signature “save“ in ASCII code
(hex-Code: 0x65766173) or “evas“
(hex-Code: 0x73617665) on sub index 1 the current parameters are not quick saved.
A succesful save procedure will be confirmed after ca. 400 ms by the TxSDO (1st
byte = 0x80). During saving no CAN telegrams can be sent or received.
Table 30
CAN: COB-ID SYNC message
Index
Sub Index Name
Format
Attr. Map Default
Meaning
0x1005 00
COB-ID
SYNC
Unsigned 32 RO
No
0x80000080 Sync Consumer,
Sync ID = 0x80
Table 31
CAN: Device Name
Index
Subindex Name
Format
Attr. Map Default
Meaning
0x1008 00
Device Name Unsigned 8
RO
NO
3
number of sub-
indexes
01
Name 1
Vis.-String
RO
NO
„G_73“
“device name“
02
Name 2
Vis.-String
RO
NO
„350Z“
03
Name 3
Vis.-String
RO
NO
„A “
Table 32
CAN: Hardware Version
Index
Subindex Name
Format
Attr. Map Default
Meaning
0x1009 00
Hardware Ver
-
sion
Vis.-String
RO
NO
„A2“
“version of circuit
board“
Table 33
CAN: Software Version
Index
Subindex Name
Format
Attr. Map Default
Meaning
0x100A 00
Software Ver
-
sion
Vis.-String
RO
NO
„1.14“
“firmware version“
Table 34
CAN: Save Parameter
Index
Sub Index Name
Format
Attr. Map Default
Meaning
0x1010 00
Save Parame
-
ter
Unsigned 8
RO
No
0x01
number of sub
indexes
01
Save All
Unsigned 32 RW
No
0x00000001 Save All is possible