Profibus Interface (HG 73351)
English, Revision 03, Date: 20.11.2015
38
7
Profibus Interface (HG 73351)
The Node-ID has to be selected via the serial monitor described in section 5.1 on page
73351A0.GSD
(see section D on page 45 in the appendix) two
different configurations can be displayed, see below. The order of the bytes within a
16 bit word can be altered using the Profibus menu, point
(see section 5.1.4 on
page 17).
1.
Reading only of 5 input bytes according to the following table:
The meaning of the status bits is determined as follows:
2.
In addition to item 1 the frequencies of the two wires can be adjusted
If values outside of the defined value range are transmitted they will be ignored. Fre-
quency changes are carried out with the frequency switch time specified in the Tech-
nical Data.
Value
Format
Range
Description
Status
unsigned 8
0..0xff
Status bits according to Table 46 below
X1
signed 16
-255…..+255
-255 [mm]…..+255 [mm]
X2
signed 16
-255…..+255
-255 [mm]…..+255 [mm]
Table 45
Format of the 5 Profibus Input Bytes
Bit number
Valency
Description
7
0x80
Us1 has exceeded the set threshold for channel 1
6
0x40
Us2 has exceeded the set threshold for channel 2
5
0x20
Not used
4
0x10
Calibration active
3
0x08
DC supervision Ud1 OK
2
0x04
DC supervision Ud2 OK
1
0x02
Not used
0
0x01
The checksum of the EEPROM parameters is wrong
Table 46
Profibus: Meaning of the Profibus Status bits
Wire
Format
Range
Description
F1
Unsigned 16
1000....28000
Wire frequency channel 1 [kHz]
F2
Unsigned 16
1000....28000
Wire frequency channel 2 [kHz]
Table 47
Profibus: Setting the wire frequencies