CAN Interface (HG 73350)
English, Revision 03, Date: 20.11.2015
27
6.5.2
Manufacturer entries
0x1A01
0
RO
Number of Objects mapped to Transmit PDO_2
1
RO
Specification of Appl. Object 1
2
RO
Specification of Appl. Object 2
3
RO
Specification of Appl. Object 3
4
RO
Specification of Appl. Object 4
*) Here only the highest bit can be changed in order to temporarily disable/enable the PDO.
Manufacturer entries from 0x2000 on
Index
Subindex
Access
Content
EEProm
0x2000
0
RO
Number of Parameter
1
RW
Frequency 1
M
2
RW
Frequency 2
M
3
RW
Threshold CD1 LED
M
4
RW
Threshold CD2 LED
M
5
RW
Height of Ant 1
M
6
RW
Height of Ant 2
M
7
RW
Internal Height of Ant 1
M
8
RW
Internal Height of Ant 2
M
0x2001
0
RO
Number of Parameter
1
W
Start Ant-1 calibration
R
Stop Ant-1 calibration
2
W
Start Ant-2 calibration
R
Stop Ant-2 calibration
0x2002
0
RO
Number of Parameter
1
RW
Node Baudrate
C
2
RW
Node ID
C
3
RW
Node Config
C
Table 20
CAN: overview of object directory, manufacture specific entries from
0x2000 on
Communication specific entries located from 0x1000 to 0x1FFF
Index
Subindex
Access
Content
EEProm
Table 19
CAN: overview of object directory, communication specific entries
between 0x1000 and 0x1FFF (part 3 of 3)