![Gotting HG 71451-A Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/gotting/hg-71451-a/hg-71451-a_manual_2247531011.webp)
Components and Operation
English, Revision 03, Date: 07.02.2012
11
1.
Simple reading of the antenna with 3 input bytes according to the following table
2.
Read antenna with 3 input bytes (Table 7) and send delete statement with one
output byte (Table 8)
The output byte has to be applied according to the following table:
If a new positioning pulse shall be released at the transponder just read, e. g.
after a change in the direction of travel, the delete statement has to be send.
This instruction sets the number of the last read transponder to zero. The delete
statement will be initiated by a rising edge of the CLR-bit; i. e. first the status
byte should be transferred with a deleted CLR-bit. The current status will be indi-
cated in the status byte (see Table 11 on page 12).
Byte #
Length
Type
Sequence
Signification
1
2 Byte
unsigned int
Lo Byte
read transponder
code
2
Hi Byte
3
1 Byte
unsigned char
Status (according
to Table 11 below
Table 6
Structure of the 3 Profibus Input Bytes
Byte #
Length
Type
Sequence
Signification
1
2 Byte
unsigned int
Lo Byte
read transponder
code
2
Hi Byte
3
1 Byte
unsigned char
status (according to
Table 11 below)
Table 7
Structure of the 3 Profibus Input Bytes
Byte #
Length
Type
Sequence
Signification
1
1 Byte
unsigned char
Instruction bit
(according to Table
12 below)
Table 8
Structure of the Profibus Output bytes