Mounting and Setup
English, Revision 03, Date: 07.02.2012
16
3.2.2
Mounting in Tough Material (e. g. tar)
-
Protection tube necessary (e. g. of fiber-reinforced plastic material). Choose the
diameter of the load accordingly.
-
Arrange the transponders unmounted or vertical in foamed material (otherwise a
position error will occur).
-
To protect the transponder use either a covering cap or apply an epoxy resin layer
(thickness approximately 1 cm). The drill hole mouth should be wide enough so
that the cover cannot press on the transponder.
Figure 5
Metal-free area around the transponder HG 71325
3.3
Reading Antenna
3.3.1
Mounting Drills
Figure 6
Mounting of the identifying antenna: Position and size of the drilling
To achieve a maximum range (> 50 mm) of the reading distance, it is recommendable
to mount a 10 mm plastic plate or a 10 mm spacing bolt between the steel or alumin-
ium rack and the reading antenna. When using spacing bolts a large washer is to be
placed under the reading antenna.
e. g. air cushion foil
or plastics spring
metallfreier Raum
G 71451-A