Transponder
HG G-70661XA
Technical Data
- Dimensions
ø74.6 mm x 35,4 mm height (±1 mm)
- Weight
200 g
- Material
Casing: ABS-PC Pulse 920MG
Sealing compound: Polyurethane casting resin
- Mechanical Pressure
max. 490 N/cm²
- Operating Temperature
-20 to +60
o
C
- Storage Temperature
-20 to +60
o
C
- Protection Class
IP 67
- Data
32 Bit useful data in EEPROM
- Reading distance
50... 90 mm
- Nominal reading/writing distance with Antenna HG 98780: 75 mm
Date: 23.07.2020
English, Revision: 04
Author(s): RAD/WM/GW
Mounting Instructions
Do not mount a transponder directly on
metal!
The minimum distance around the
transponder as shown to the right should be
observed.
1 – On the Ground
The transponder has to be mounted on
even ground using a metal screw and a
washer. The maximum fastening torque is
not allowed to exceed 4 Nm. The diameter
of the metal washer should not extend
18 mm.
2 – In the Ground
The following equipment is required (not in
-
cluded in the scope of supply):
-
Rotary hammer drill
-
Core bit (ø 85 mm)
-
ø 8 to 10 mm drill bit
-
hammer and chisel
-
suitable sealing material
1. It is recommended that a test hole be
drilled prior to installing the transponder
network.
2. The position of the transponder should
be premarked and a centering hole
should be drilled with an appropriate
drill bit.
3. A hole may then be drilled with a
diameter of 85 mm to a depth of min.
50 mm (A). Any loose material must
be removed and the floor of the hole
has to be leveled out (B).
4. Afterwards fill the hole with sealing
compound up to a height of 40 mm
below the road (C). A delay may be
necessary before placing the tran
-
sponder into position, dependent
upon type and viscosity of the seal
-
ing compound.
5. The transponder is then to be placed
centered on the sealing compound
(C). Then fill the hole up with more
sealing compound.
Screw
Washer
Transponder
approx. 200 mm
approx. 100 mm
Metal-free area
Transponder
Sealing Compound
1
2
85 mm
min.
50
mm
40 mm
Sealing Compund
75 mm
35 mm
Transponder