![GOSUNCN ME3630 Series Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/gosuncn/me3630-series/me3630-series_command-reference-manual_2247368025.webp)
All Rights reserved, No Spreading without GOSUNCN Permission
24
AT Command Reference Guide of Module Product
ME3630
<val>:
0
DCE transmits limited headers and trailers and numeric text.
1
DCE transmits full headers and trailers and verbose response text.
NOTE: if parameter <val> is omitted, the command has the same behavior as ATV0. The define value is 1, and the value can be available from
the command AT&V or AT\S.
3.10.
AT+CFUN Set Phone Functionality
Set command selects
the level of functionality <fun> in the MT. Level "full functionality" is where the highest level of power is
drawn. "Minimum functionality" is where minimum power is drawn. Level of functionality between these may also be specified by
manufacturers. When supported by manufacturers, MT resetting with <rst> parameter may be utilized.
NOTE: issuing AT+CFUN=4[,0] actually causes the module to perform either a network deregistration and a SIM deactivation.
Test command returns values supported as a compound value.
Command
Response
+CFUN=[<fun>[,<rst>]]
<CR><LF>OK<CR><LF>
or
<CR><LF>+CME ERROR: <err><CR><LF>
+CFUN?
<CR><LF>+CFUN: <fun><CR><LF>
<CR><LF>OK<CR><LF>
or
<CR><LF>+CME ERROR: <err><CR><LF>
+CFUN=?
<CR><LF>+CFUN: (list of supported <fun>s), (list of supported <rst>s) <CR><LF>
<CR><LF>OK<CR><LF>
or
<CR><LF>+CME ERROR: <err><CR><LF>
Parameter
<fun>:
0
minimum functionality (MT before setting must not 7)
1
full functionality (MT before setting must not 7) (factory default)
4
disable phone both transmit and receive RF circuits (MT before setting must not 7)
5
Factory test mode
6 Reset module
7
Offline Mode,in this status, the NV is lost, and the module can’t register to network,we recommend to restore the NV.
8
module enter sleep mode, no USB interface enumerated(only supported by ME3630-J2A)
<rst>:
0
no need to reset the module to make <fun> effect.
1
need to reset the module to make <fun> effect.
NOTE: This shall be always default 0 when <rst> is not given
Example
AT+CFUN?